National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
COUPLER , DIRECTIONAL
Definition:
AN ITEM SPECIFICALLY DESIGNED TO BE INSERTED INTO A TRANSMISSION LINE, WAVEGUIDE OR COAXIAL TRANSMISSION LINE TO PROVIDE A SUITABLE TEST OUTLET. THE TEST SIGNAL IS ATTENUATED TO A PREDETERMINED VALUE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
NH13355 | 98821 | A | 5 | 2 | 5 | ZZ | ||
D-500-N456-121-01 | 06090 | A | 5 | 9 | 5 | ZZ | ||
05A235-04 | 1W025 | A | 5 | 9 | E | ZZ | ||
05A008-04 | 1W025 | A | 3 | 2 | E | ZZ | ||
DBE-34005-M | 79714 | A | 5 | 2 | 5 | ZZ |
CAGE Information
Code | Company |
---|---|
06090 | TYCO ELECTRONICS CORPORATION DIV RAY |
98821 | NORTH HILLS SIGNAL PROCESSING CORP. |
1W025 | NORTHROP GRUMMAN SYSTEMS CORPORATION |
79714 | TECHNITROL INC |
Federal Supply Class
Title
ANTENNAS, WAVEGUIDES, AND RELATE
Inclusions:
INCLUDES AERIALS; MASTS; TOWER EQUIPMENT; ATTENUATORS; COUPLERS; TRANSMISSION LINES.
Exclusions:
EXCLUDES TOWER STRUCTURES.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
APGF | DESIGN TYPE | BIDIRECTIONAL |
ANKZ | RADIO FREQUENCY RATING | NOT RATED |
BGPY | TERMINAL FITTING NAME | WIRE LEADS |
ABKW | OVERALL HEIGHT | 0.700 INCHES MAXIMUM |
APQB | UNIT TYPE | TRANSMISSION LINE |
BGPZ | TERMINAL FITTING CONTROLLING AGENCY | NORTHROP CORPORATION |
ABMK | OVERALL WIDTH | 0.460 INCHES MAXIMUM |
BGPX | POWER LOSS IN DECIBELS | NOT RATED |
ABHP | OVERALL LENGTH | 3.400 INCHES MAXIMUM |