National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
COUPLER , DIRECTIONAL
Definition:
AN ITEM SPECIFICALLY DESIGNED TO BE INSERTED INTO A TRANSMISSION LINE, WAVEGUIDE OR COAXIAL TRANSMISSION LINE TO PROVIDE A SUITABLE TEST OUTLET. THE TEST SIGNAL IS ATTENUATED TO A PREDETERMINED VALUE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
ES8197-01 | 20418 | C | 3 | 2 | A | ZZ | ||
WC6260 | 50478 | A | 5 | 2 | A | ZZ |
CAGE Information
Code | Company |
---|---|
20418 | DRS SUSTAINMENT SYSTEMS INC. DIV DRS |
50478 | GENERAL DYNAMICS SATCOM TECHNOLOGIES |
Federal Supply Class
Title
ANTENNAS, WAVEGUIDES, AND RELATE
Inclusions:
INCLUDES AERIALS; MASTS; TOWER EQUIPMENT; ATTENUATORS; COUPLERS; TRANSMISSION LINES.
Exclusions:
EXCLUDES TOWER STRUCTURES.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
APGF | DESIGN TYPE | BIDIRECTIONAL |
ABMK | OVERALL WIDTH | 5.550 INCHES NOMINAL |
ABHP | OVERALL LENGTH | 4.000 INCHES MINIMUM |
BGPS | VOLTAGE STANDING WAVE RATIO AT REFERENCE FREQUENCY | 1.05 TO 1 MAX PRIMARY ARM |
ANKZ | RADIO FREQUENCY RATING | 16.4 GIGAHERTZ MINIMUM AND 16.6 GIGAHERTZ MAXIMUM |
BGPY | TERMINAL FITTING NAME | CHOKE FLANGE IAW M3922/59-001; COVER FLANGE IAW M3922/53-001 |
SPCL | SPECIAL TEST FEATURES | LEAK RATE NOT TO EXCEED0.001 CUBIC CENTIMETERS PER MIN. |
APQB | UNIT TYPE | WAVEGUIDE |
BGPX | POWER LOSS IN DECIBELS | NOT RATED |