Follow Us on Google+

Request A Price Quote:

National Stock Number (NSN) Output Data

NSN:
NIIN:
Item Name:
COUPLER , DIRECTIONAL

Definition:

AN ITEM SPECIFICALLY DESIGNED TO BE INSERTED INTO A TRANSMISSION LINE, WAVEGUIDE OR COAXIAL TRANSMISSION LINE TO PROVIDE A SUITABLE TEST OUTLET. THE TEST SIGNAL IS ATTENUATED TO A PREDETERMINED VALUE.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
MDC6Z26-30 52335 A 5 2 E TX
2020-5089 26805 A 5 9 5 TX
562478-4 56232 A 5 2 5 TX
4014C30 99899 A 5 2 E TX
2921474-4 10001 A 3 2 A TX

CAGE Information

Code Company
10001 NAVAIR AND NAVSEA MANAGED ORIGINAL D
52335 DAL-TECH DEVICES INC. DBA MICROWAVE
26805 TYCO ELECTRONICS CORP
56232 LOCKHEED MARTIN CORPORATION DBA LOCK
99899 L-3 COMMUNICATIONS CORPORATION DBA N

Federal Supply Class

Title

ANTENNAS, WAVEGUIDES, AND RELATE

Inclusions:

INCLUDES AERIALS; MASTS; TOWER EQUIPMENT; ATTENUATORS; COUPLERS; TRANSMISSION LINES.

Exclusions:

EXCLUDES TOWER STRUCTURES.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
APGF DESIGN TYPE BIDIRECTIONAL
APGF DESIGN TYPE BIDIRECTIONAL
BGPS VOLTAGE STANDING WAVE RATIO AT REFERENCE FREQUENCY 1.25 TO 1 AT 4 TO 8 GHZ
ABHP OVERALL LENGTH 1.750 INCHES NOMINAL
APQB UNIT TYPE COAXIAL LINE
ABKW OVERALL HEIGHT 0.375 INCHES NOMINAL
BGPX POWER LOSS IN DECIBELS 30.0
ANKZ RADIO FREQUENCY RATING 4.0 GIGAHERTZ MINIMUM AND 8.0 GIGAHERTZ MAXIMUM
ABMK OVERALL WIDTH 1.016 INCHES NOMINAL
BGPY TERMINAL FITTING NAME FEMALE COUPLING
BGQC TERMINAL FITTING USAGE DESIGN MAIN LINE AND SECONDARY LINE