National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
AMPLIFIER , RADIO FREQUENCY
Definition:
AN ELECTRONIC DEVICE WHOSE RADIO FREQUENCY INPUT SIGNALS CONTROL POWER FROM A SOURCE INDEPENDENT OF THE INPUT SIGNALS, AND DELIVERS RADIO FREQUENCY OUTPUT SIGNALS OF GREATER AMPLITUDE WITH RESPECT TO CURRENT AND/OR VOLTAGE. THE OUTPUT SIGNALS CHARACTERISTICS ARE UNIFORMLY RELATED TO THE INPUT SIGNALS. IT OPERATES AT FREQUENCIES ABOVE 20 KILOHERTZ.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
247ASC0409-001 | 30003 | A | 3 | 2 | A | TX | ||
DA21B | 19645 | A | 5 | 2 | 5 | TX |
CAGE Information
Code | Company |
---|---|
19645 | DATA DEVICE CORPORATION DBA FORMELY |
30003 | NAVAL AIR SYSTEMS COMMAND |
Federal Supply Class
Title
AMPLIFIERS
Inclusions:
INCLUDES AUDIO AMPLIFIERS, COMPLEMENTARY AMPLIFIERS, AMPLIFIERS, OPERATIONAL AMPLIFIERS, POWER AMPLIFIERS, RADIO FREQUENCY AMPLIFIERS, SIGNAL AMPLIFIERS, VIDEO AMPLIFIERS, AND MAGNETIC AMPLIFIERS.
Exclusions:
EXCLUDES MULTI-FUNCTIONAL ITEMS SUCH AS AMPLIFIER-DETECTOR, AMPLIFIER-MIXER AND MICROCIRCUIT DEVICES.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AQZF | CONTROL TYPE | REMOTE |
AJKH | IDENTIFICATION DESIGNATOR | 247ASC0409-001-30003 |
AGTA | BASIC SHAPE STYLE | RECTANGULAR OR SQUARE |
AMQY | INSTALLATION DESIGN | MECHANICAL |
ABKW | OVERALL HEIGHT | 0.780 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 1.200 INCHES MAXIMUM |
ABHP | OVERALL LENGTH | 1.800 INCHES MAXIMUM |
BJBP | CONNECTION TYPE AND LOCATION | PIN BOTTOM |
BJBW | CONNECTION CONTACT TYPE AND QUANTITY | 10 PIN EXTERNAL |
ADZC | ENVIRONMENTAL PROTECTION | SALT SPRAY RESISTANT AND SHOCK RESISTANT AND MOISTURE PROOF AND VIBRATION |
AFSU | AVERAGE LIFE MEASUREMENT | NOT RATED |
BHSX | CIRCUIT CONSTRUCTION TYPE | SOLID STATE |
AKNA | INCLOSURE TYPE | ENCASED |
BKFB | EXTERNAL DC OPERATING VOLTAGE IN VOLTS | 12.0 NOMINAL SINGLE VOLTAGE |
AFGA | OPERATING TEMP RANGE | -55.0/+100.0 DEG CELSIUS |
ALBM | OPERATING CONTROL METHOD | AUTOMATIC |