Definition:
A TRANSFORMER WHICH INCORPORATES THE PRIMARY AND SECONDARY FUNCTIONS INTO A SINGLE WINDING, WHICH IS COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, AND IS DESIGNED TO CHANGE THE RELATIONSHIP OF VOLTS AND AMPERES BETWEEN THE ENTIRE WINDING AND ITS TAPS. INCLUDES MULTIPLE WINDING TRANSFORMERS OF LIKE DESIGN AND ITEMS IN WHICH A VARIATION OF THE TURNS RATIO OR INDUCTIVE RATIO OF INDUCTIVE COUPLING IS ACCOMPLISHED BY CONNECTION TO FIXED TERMINALS. ALSO, INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO IN PROGRESSIVE INCREMENTS, BY MEANS OF A SHAFT, VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OF SIMILAR DESIGN. EXCLUDES TRANSFORMER (1), POWER; TRANSFORMER (1), PULSE.
CAGE Information
Code | Company |
---|---|
76301 | BOEING COMPANY THE DBA BOEING |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
THSD | THREAD SERIES DESIGNATOR | UNEF SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED BUSHING SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY, VARIABLE AUTOTRANSFORMER TYPE SINGLE COMPONENT |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
ADAR | BODY OUTSIDE DIAMETER | 1.950 INCHES MINIMUM AND 2.050 INCHES MAXIMUM |
AAJF | THREAD DIRECTION (NON-CORE) | RIGHT-HAND SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY INPUT |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 8.900 INCHES MAXIMUM |
TTQY | TERMINAL TYPE AND QUANTITY | 7 TAB, SOLDER LUG |
CQJX | NOMINAL THREAD SIZE | 0.375 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 5.0 AMPERES NOMINAL B SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
CBBL | FEATURES PROVIDED | W/SWITCH |
AGAV | END ITEM IDENTIFICATION | NAV-8A/B/CD/CN; WSD: AIRCRAFT, HARRIER AV-8B |
CRMJ | WINDING POWER RATING | 140.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
FEAT | SPECIAL FEATURES | INCLUDES POTENTIOMETER; WEAPON SYSTEM ESSENTIAL |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
PKWT | UNPACKAGED UNIT WEIGHT (NON-CORE) | 2.000 POUNDS |
AAJD | THREAD CLASS (NON-CORE) | 2A SINGLE GROUP |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
CWJS | WINDING OPERATING VOLTAGE | 0.00 AC POUNDS PER HOUR DRY SINGLE COMPONENT SINGLE PRIMARY OUTPUT AND 28.00 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT SINGLE PRIMARY OUTPUT |