Part Number
Part Number:
NSN:
NIIN:
Item Name:
REGULATOR , ENGINE GENERATOR
Definition:
A REGULATOR DESIGNED TO AUTOMATICALLY MAINTAIN THE CURRENT AND/OR VOLTAGE OUTPUT OF AN ENGINE GENERATOR WITHIN SPECIFIED LIMITS, REGARDLESS OF VARIATION OF LOAD OR INPUT VOLTAGES. MAY INCLUDE CUTOUT RELAY. DOES NOT INCLUDE ITEMS IN WHICH REGULATION IS ACCOMPLISHED BY TRANSFORMER ACTION. SEE ALSO REGULATOR, CURRENT AND REGULATOR, VOLTAGE.
CAGE Information
Code | Company |
---|---|
11083 | CATERPILLAR INC. DBA CATERPILLAR DIV |
Federal Supply Class
Title
ENGINE ELECTRICAL SYSTEM COMPONE
Inclusions:
INCLUDES GENERATORS; MAGNETOS; SPARK PLUGS; IGNITION COILS; IGNITION DISTRIBUTORS; ENGINE VOLTAGE REGULATORS; IGNITION HARNESS ASSEMBLIES; STARTING MOTORS FOR ENGINES.
Exclusions:
EXCLUDES VEHICULAR LIGHTING FIXTURES (FSC 6220) AND AIRCRAFT GENERATORS (FSC 2925).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABTD | MOUNTING SLOT WIDTH | 0.338 INCHES MAXIMUM |
ANYX | CUTOUT VOLTAGE RATING | NOT RATED |
ADNY | DISTANCE BETWEEN HOLES ALONG LENGTH | 5.968 INCHES MINIMUM |
ANPP | OUTPUT VOLTAGE RATING IN VOLTS | 27.0 MINIMUM |
ADZC | ENVIRONMENTAL PROTECTION | FUNGUS RESISTANT |
ANYD | SYSTEM GROUND POLARITY | NEGATIVE |
ANPP | OUTPUT VOLTAGE RATING IN VOLTS | 29.0 MAXIMUM |
ABTB | MOUNTING HOLE DIAMETER | 0.338 NOMINAL CENTIMETERS |
AARB | TERMINAL TYPE | CONNECTOR, RECEPTACLE W/INTERNAL CONTACTS |
ABVG | MOUNTING SLOT LENGTH | 0.443 INCHES MINIMUM |
ANYP | OUTPUT CURRENT RATING IN AMPS | 38.0 MINIMUM |
APAW | CENTER TO CENTER DISTANCE BETWEEN SLOTTED HOLES AND PLAIN HOLES ALONG WIDTH | 5.365 NOMINAL MILS |
ANYC | SYSTEM VOLTAGE RATING | 28.0 |
ANYK | CURRENT REGULATOR UNIT QUANTITY | 1 |
APAT | CENTER TO CENTER DISTANCE BETWEEN SLOTTED HOLES ALONG LENGTH | 5.968 NOMINAL MILS |
ANYH | VOLTAGE REGULATOR UNIT QUANTITY | 1 |
ABTB | MOUNTING HOLE DIAMETER | 0.318 NOMINAL MILS |
ANYR | CIRCUIT CONTROL DEVICE TYPE | CUTOUT RELAY |
ANZB | REVERSE CURRENT OVERLOAD CIRCUIT BREAKER | NOT INCLUDED |
APAW | CENTER TO CENTER DISTANCE BETWEEN SLOTTED HOLES AND PLAIN HOLES ALONG WIDTH | 5.385 NOMINAL CENTIMETERS |
ANYJ | CURRENT REGULATOR UNIT TYPE | WIRE WOUND COIL |
APAT | CENTER TO CENTER DISTANCE BETWEEN SLOTTED HOLES ALONG LENGTH | 6.032 NOMINAL CENTIMETERS |
AARA | TERMINAL QUANTITY | 2 |
ADZC | ENVIRONMENTAL PROTECTION | CORROSION RESISTANT |
ANYE | VOLTAGE REGULATOR UNIT TYPE | WIRE WOUND COIL |
AGBC | SHOCK MOUNT | NOT PROVIDED |
ABVG | MOUNTING SLOT LENGTH | 0.463 INCHES MAXIMUM |
ANYZ | CUTOUT CURRENT RATING IN AMPS | NOT RATED |
ADNY | DISTANCE BETWEEN HOLES ALONG LENGTH | 6.032 INCHES MAXIMUM |
ANYS | CUT-IN VOLTAGE RATING | 25.0 MINIMUM |
ANZC | FIELD RELAY UNIT | NOT INCLUDED |
ANYP | OUTPUT CURRENT RATING IN AMPS | 42.0 MAXIMUM |
ANZF | CONDUIT CONNECTION QUANTITY | 2 |
ALBH | RADIO INTERFERENCE SHIELDING | PROVIDED |
ABTD | MOUNTING SLOT WIDTH | 0.318 INCHES MINIMUM |
ADZC | ENVIRONMENTAL PROTECTION | WATERTIGHT |
ANZE | TERMINAL ENCASEMENT | ENCASED |
ANYS | CUT-IN VOLTAGE RATING | 27.0 MAXIMUM |
ADER | MOUNTING STYLE | TWO PLAIN HOLES TWO SLOTTED HOLES |