Part Number
Definition:
AN ITEM CONSISTING OF A REFRIGERATION COMPRESSOR AND PRIME MOVER, IT MAY BE OPEN OR ENCLOSED IN A HERMETICALLY SEALED HOUSING, HAVING INLET AND OUTLET CONNECTIONS AND FACILITIES FOR MOUNTING.
CAGE Information
Code | Company |
---|---|
10855 | CARRIER CORPORATION DIV CARRIER TRAN |
Federal Supply Class
Title
REFRIGERATION AND AIR CONDITIONI
Inclusions:
INCLUDES HEAT EXCHANGER EQUIPMENT; REFRIGERANT STRAINERS; REFRIGERATION COMPRESSORS; AIR CONDITIONING AND REFRIGERATION SERVICING EQUIPMENT, SUCH AS CHARGING AND TESTING MANIFOLDS, LINES AND UNITS; OPERATING COMPONENTS OF REFRIGERATION AND AIR CONDITIONING EQUIPMENT, PLANTS, AND SYSTEMS CLASSIFIED IN CLASSES 4110 AND 4120.
Exclusions:
EXCLUDES REFRIGERATION AND AIR CONDITIONING PLANTS (SEE CLASSES 4110 AND 4120): COLLECTIONS OF REFRIGERATION COMPONENTS "PACKAGED" AS A UNIT INCLUDING A REFRIGERATION COMPRESSOR, CONDENSER, EVAPORATOR, ETC., SPECIFICALLY DESIGNED AND TAILORED FOR APPLICATIONS SUCH AS WALK-IN TYPE REFRIGERATORS. INDIVIDUAL COMPONENTS OF THE "PACKAGED" UNIT WILL BE CLASSIFIED IN CLASS 4130, OR AS OTHERWISE SPECIFICALLY PRESCRIBED BY THE INDEXES AND STRUCTURE OF THE FSC. THE COMPLETE "PACKAGE" UNIT WILL BE CLASSIFIED IN CLASS 4110.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ZZZY | REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | AS DIFFERENTIATED BY REPLY TO PAC AAYE |
FREQ | FREQUENCY IN HERTZ | 60.0 |
AAXV | UNLOADER TYPE | AUTOMATIC |
AAYA | CYLINDER ARRANGEMENT STYLE | "W" DESIGN |
AAXQ | COMPRESSED GAS COOLING MEDIUM | SALT WATER |
AAXS | PRIME MOVER COOLING MEDIUM | AIR |
AAXP | COOLING SYSTEM DESIGN | MIXED |
AAYS | COMPRESSOR SPEED AT RATED CAPACITY IN RPM | 1750.0 |
AAYF | SUCTION PRESSURE | 30.0 POUNDS PER SQUARE INCH |
AAXJ | DUTY CYCLE IN PERCENT | 100 |
AKDJ | PRIME MOVER TYPE | ELECTRIC MOTOR |
FAAZ | PHASE | THREE |
CSBH | VOLTAGE IN VOLTS AND CURRENT TYPE | 440.0 AC |
AAXW | BRAKE HORSEPOWER REQUIRED | 74.000 |
AAXZ | CYLINDER QUANTITY | 12 |
AAYT | INTAKE CONNECTION QUANTITY | 1 |
AAXR | COMPRESSOR COOLING MEDIUM | REFRIGERANT |
CQJY | CURRENT TYPE AND RATING IN AMPS | 91.0 AC |
AAYW | DISCHARGE CONNECTION TYPE | ROUND FLANGE |
AAYD | STAGE QUANTITY | 1 |
AAYV | DISCHARGE CONNECTION QUANTITY | 1 |
AAXX | MOUNTING TYPE | BASE |
AAXK | GAS FOR WHICH DESIGNED | REFRIGERANT R-12 |
AAXM | DISCHARGE PRESSURE | 126.600 POUNDS PER SQUARE INCH GAGE |
AAYU | INTAKE CONNECTION TYPE | SQUARE FLANGE |
CSFH | TEMP RATING PER FUNCTION | 105.0 DEG FAHRENHEIT DISCHARGE AND 32.4 DEG FAHRENHEIT SUCTION |
AAYE | REFRIGERATION FLOW RATE IN TONS PER HOUR | 55.0 |
AAXY | RECIPROCATING COMPRESSOR DESIGN | SINGLE ACTING |
AAXL | DISCHARGE FLOW RATE | NOT RATED |