Part Number
Definition:
AN ITEM HAVING EITHER A SINGLE TAPPED WINDING (AUTOTRANSFORMER TYPE), OR TWO OR MORE WINDINGS DESIGNED TO FURNISH INDUCTIVE REACTANCE AND/OR TRANSFER ELECTRICAL ENERGY IN CIRCUITS BY MEANS OF A MAGNETIC FIELD. IT IS SO DESIGNED THAT ITS ENTIRE INTENDED RANGE OF OPERATIONS IS ABOVE 20 KILOHERTZ (KILOCYCLES). THE MINIMUM VALUE MAY EXTEND INTO THE AUDIO FREQUENCY RANGE (BELOW 20 KILOHERTZ). IT MAY INCLUDE INTEGRAL CAPACITORS, COILS, RESISTORS, AND ADJUSTABLE TUNING CORES. FOR ITEMS HAVING ONLY TWO ACTIVE TERMINALS SEE COIL, RADIO FREQUENCY. INCLUDES TYPES HAVING WINDINGS WHICH MAY BE MOVED WITH RESPECT TO EACH OTHER. EXCLUDES TRANSFORMER, DISCRIMINATOR.
CAGE Information
Code | Company |
---|---|
04620 | RAYCO ELECTRONIC MFG.INC. |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CQPZ | WINDING CONDUCTOR SIZE | 0.04030 INCHES AMERICAN WIRE GAGE SINGLE COMPONENT ALL SECONDARY |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
ZZZK | SPECIFICATION/STANDARD DATA | 45413-142199 MANUFACTURERS SOURCE CONTROL |
ACZB | FREQUENCY RATING | 200.0 KILOHERTZ NOMINAL SINGLE COMPONENT |
CQPZ | WINDING CONDUCTOR SIZE | 0.04030 INCHES AMERICAN WIRE GAGE SINGLE COMPONENT SINGLE PRIMARY |
BKPL | RATING METHOD | ELECTRICAL SINGLE COMPONENT SINGLE PRIMARY AND WINDING TURNS SINGLE COMPONENT SINGLE PRIMARY |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
ADAV | OVERALL DIAMETER | 1.000 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 125.0 DEG CELSIUS |
ACZP | COIL FORM TYPE | SOLID SINGLE COMPONENT |
AAJF | THREAD DIRECTION (NON-CORE) | RIGHT-HAND SINGLE GROUP |
ABHY | TURN QUANTITY | 18 SINGLE COMPONENT ALL SECONDARY |
ABHY | TURN QUANTITY | 18 SINGLE COMPONENT SINGLE PRIMARY |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 6 WIRE LEAD |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.112 INCHES SINGLE GROUP |
AKPV | MOUNTING FACILITY QUANTITY | 1 SINGLE GROUP |
AAJD | THREAD CLASS (NON-CORE) | 2A SINGLE GROUP |
ABHP | OVERALL LENGTH | 0.769 INCHES NOMINAL |
BKPL | RATING METHOD | ELECTRICAL SINGLE COMPONENT ALL SECONDARY AND WINDING TURNS SINGLE COMPONENT ALL SECONDARY |
ACYV | INDUCTANCE RATING | 800.00 MICROHENRIES MINIMUM SINGLE COMPONENT SINGLE PRIMARY |