Part Number
Part Number:
NSN:
NIIN:
Item Name:
SWITCH , PRESSURE
Definition:
A SWITCH WHICH IS ACTUATED BY CHANGES IN PRESSURE OF ANY GAS OR LIQUID OR BY CHANGES IN A VACUUM ACTING UPON ITS SENSING ELEMENT. EXCLUDES BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; AND SWITCH, SENSITIVE.
CAGE Information
Code | Company |
---|---|
60029 | GE AVIATION SYSTEMS LLC DBA GE AVIAT |
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CTZL | PRESSURE CONNECTOR TYPE | PLAIN, THREADED INTERNAL ALL CONNECTIONS |
CTZL | PRESSURE CONNECTOR TYPE | PLAIN, THREADED INTERNAL ALL CONNECTIONS |
AAJD | THREAD CLASS | 2B ALL PRESSURE CONNECTION |
CQYJ | MOUNTING FACILITY PATTERN | ISOSCELES TRIANGLE |
CBBL | FEATURES PROVIDED | ELECTRICAL ACCESS PORT |
THSD | THREAD SERIES DESIGNATOR | UNEF ALL PRESSURE CONNECTION |
CSCC | SENSING ELEMENT BURST PRESSURE | 7500.00 POUNDS PER SQUARE INCH |
AFDT | SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 0.750 INCHES NOMINAL |
AXGY | MOUNTING METHOD | BASE AND UNTHREADED HOLE |
CTHF | CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD SINGLE VOLTAGE |
ABHP | OVERALL LENGTH | 6.112 INCHES NOMINAL |
MEDA | MEDIA FOR WHICH DESIGNED | LIQUID |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
CTYX | CONTACT STIMULUS RATING | 1500.00 ACTUATION POINT NOMINAL POUNDS PER SQUARE INCH AND 1000.00 DEACTUATION POINT NOMINAL POUNDS PER SQUARE INCH AND 500.00 DIFFERENTIAL POINT NOMINAL POUNDS PER SQUARE INCH |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
AFDS | LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 1.500 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 3.562 INCHES MAXIMUM |
AFDV | LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 1.375 INCHES NOMINAL |
AARX | INSIDE DIAMETER | 0.438 INCHES NOMINAL ALL CONNECTIONS |
STYL | STYLE DESIGNATOR | RECTANGULAR |
CQJB | PROOF PRESSURE | 4500.00 POUNDS PER SQUARE INCH |
CMLP | THREAD QUANTITY PER INCH | 32 ALL PRESSURE CONNECTION |
CSCF | TERMINAL TYPE | THREADED STUD |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 27.0 DC AT SEA LEVEL SINGLE VOLTAGE |
ADAQ | BODY LENGTH | 5.000 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.275 INCHES NOMINAL |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 1.500 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 1.500 INCHES NOMINAL |
CQJX | NOMINAL THREAD SIZE | 0.438 INCHES SINGLE PRESSURE CONNECTION |
AJZC | PRESSURE SWITCH TYPE | DIFFERENTIAL |
AWTN | OPERATING TEMP RATING | -65.0 DEG FAHRENHEIT MINIMUM AND 250.0 DEG FAHRENHEIT MAXIMUM |