TRANSFORMER , POWER

Definition:

A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.

CAGE Information

Code Company
07031 TEMPO INSTRUMENT INC DEFENSE ELECTRO

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
CWJS WINDING OPERATING VOLTAGE 1.40 AC POUNDS PER HOUR WET SINGLE COMPONENT 4TH SECONDARY
CQLC WINDING TAP LOCATION (NON-CORE) CENTER TAP SINGLE COMPONENT 4TH SECONDARY
AXGY MOUNTING METHOD TAB SINGLE GROUP
ABMK OVERALL WIDTH 1.200 INCHES MAXIMUM
CWJS WINDING OPERATING VOLTAGE 0.25 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY
AARG RELIABILITY INDICATOR NOT ESTABLISHED
AEHZ MAXIMUM OPERATING TEMP 130.0 DEG CELSIUS
AARD DUMMY TERMINAL QUANTITY (NON-CORE) 1
CQLC WINDING TAP LOCATION (NON-CORE) MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT 3RD SECONDARY
ABHP OVERALL LENGTH 1.200 INCHES MAXIMUM
CQLC WINDING TAP LOCATION (NON-CORE) CENTER TAP SINGLE COMPONENT SINGLE PRIMARY
ABKW OVERALL HEIGHT 1.160 INCHES MAXIMUM
CWJS WINDING OPERATING VOLTAGE 0.25 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY
TTQY TERMINAL TYPE AND QUANTITY 11 PIN AND 44 WIRE LEAD
CWJS WINDING OPERATING VOLTAGE 0.75 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY AND 0.90 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY AND 0.75 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY AND 0.90 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY
ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
CWJS WINDING OPERATING VOLTAGE 2.80 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
ACZB FREQUENCY RATING 50.0 KILOHERTZ NOMINAL SINGLE COMPONENT
ZZZK SPECIFICATION/STANDARD DATA 78711-T235A434 MANUFACTURERS SOURCE CONTROL
AKNA INCLOSURE TYPE OPEN
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 4 SECONDARY SINGLE COMPONENT