Part Number
Definition:
AN ITEM CONSISTING OF INSULATING MATERIAL, WHICH IS SPECIFICALLY DESIGNED TO HAVE FASTENED THEREON, OR ON WHICH ARE FASTENED TERMINAL(S), SUCH AS SCREWS, SOLDER LUGS, SOLDER STUDS, SOLDERLESS CONNECTORS, CLIPS, AND THE LIKE. IT IS USUALLY USED FOR JUNCTIONS OR TERMINATIONS OF WIRE OR CABLE ASSEMBLIES. IT DOES NOT INCLUDE ITEMS AS DEFINED ABOVE WITH PARTS, SUCH AS RESISTORS AND CAPACITORS MOUNTED THEREON. DO NOT USE IF A MORE SPECIFIC NAME EXISTS, SUCH AS FUSEHOLDER; HOLDER, RESISTOR; FANNING STRIP; CONTACT ASSEMBLY, ELECTRICAL; JACK ASSEMBLY, TIP; CHAMBER, CABLE TERMINAL; PANEL (2) (AS MODIFIED); CONNECTOR (AS MODIFIED). EXCLUDES TERMINAL, STUD; TERMINAL, FEEDTHRU, INSULATED; POST, BINDING, ELECTRICAL; AND CHASSIS, ELECTRICAL-ELECTRONIC EQUIPMENT. FOR ITEMS HAVING PRINTED ELECTRICAL CONDUCTOR PATHS, SEE PRINTED WIRING BOARD.
CAGE Information
Code | Company |
---|---|
83330 | DIALIGHT CORPORATION |
Federal Supply Class
Title
LUGS, TERMINALS, AND TERMINAL ST
Inclusions:
INCLUDES BINDING POSTS; BATTERY CLIPS; STUD TERMINALS; TEST CLIPS.
Exclusions:
EXCLUDES CAPS, ELECTRICAL; CLIPS, ELECTRICAL; AND CONTACTS, ELECTRICAL.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AAPB | DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 1100.0 |
ABCX | BOARD CONSTRUCTION | SOLID CONSTRUCTION |
ABGR | BOARD HEIGHT EXCLUDING TERMINALS | 0.500 INCHES |
ABCU | DISTANCE BETWEEN TERMINAL ROW CENTERS | 0.422 INCHES |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
ABGP | BOARD OVERALL WIDTH | 1.562 INCHES |
ABDX | DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITY | 0.156 INCHES |
ABGS | BASE THICKNESS | 0.312 INCHES |
ABCS | TERMINAL ROW QUANTITY | 2 |
CWLG | TERMINAL PATTERN ARRANGEMENT | MULTI-ROW |
CQCW | FEEDTHRU CONNECTION END TYPE | 857 FOURTH COMBINATION BOTH ENDS |
CRZR | FEEDTHRU TERMINAL QUANTITY | 10 SINGLE COMBINATION |
ABDU | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 4.812 INCHES |
ABDV | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.422 INCHES |
ABGN | BOARD OVERALL LENGTH | 5.125 INCHES |
AMPS | CURRENT RATING IN AMPS | 20.0 |
MATT | MATERIAL | COPPER ALLOY TERMINALS |
AAMA | MOUNTING HOLE DIAMETER | 0.175 INCHES |
CQCW | FEEDTHRU CONNECTION END TYPE | F9 15TH MATERIAL RESPONSE BOTH ENDS |
ABDW | DISTANCE FROM BOTTOM EDGE OF TERMINAL BOARD TO CENTER OF MOUNTING HOLE | 0.352 INCHES |
ABGQ | BOARD OVERALL HEIGHT | 0.500 INCHES |
CWLN | TERMINAL DESIGN | FEEDTHRU |
ABCT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.438 INCHES |
SFTT | SURFACE TREATMENT | NICKEL TERMINALS AND TIN TERMINALS |
AAQL | BODY STYLE | BARRIER TYPE |