Part Number
Part Number:
NSN:
NIIN:
Item Name:
SWITCH , THERMOSTATIC
Definition:
A SWITCH THAT IS ACTUATED BY CHANGES IN AMBIENT TEMPERATURE. EXCLUDES CIRCUIT BREAKER; CONTROL, TEMPERATURE (AS MODIFIED); FUSE (AS MODIFIED); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; AND THERMOSTAT, FLOW CONTROL. SEE ALSO CONTROL, TEMPERATURE (AS MODIFIED) AND REGULATOR, TEMPERATURE (AS MODIFIED).
CAGE Information
Code | Company |
---|---|
0B6S1 | INTERNATIONAL BUSINESS MACHINES CORP |
Federal Supply Class
Title
SWITCHES
Inclusions:
INCLUDES ROTARY, KNIFE, TOGGLE, PUSH BUTTON, MERCURY, THERMOSTATIC, AND DIFFERENTIAL PRESSURE SWITCHES.
Exclusions:
EXCLUDES SWITCHGEAR.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
STYL | STYLE DESIGNATOR | RECTANGULAR W/BRACKET |
ABKW | OVERALL HEIGHT | 0.500 INCHES NOMINAL |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE |
CSCF | TERMINAL TYPE | TAB, SOLDER LUG |
ADAU | BODY HEIGHT | 0.350 INCHES NOMINAL |
CTHF | CONTACT LOAD CURRENT RATING | 2.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT SEA LEVEL SECOND VOLTAGE |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.156 INCHES NOMINAL |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
ABMK | OVERALL WIDTH | 0.375 INCHES NOMINAL |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
ADAT | BODY WIDTH | 0.281 INCHES NOMINAL |
CTYX | CONTACT STIMULUS RATING | 149.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 139.00 DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT |
AWTN | OPERATING TEMP RATING | -65.0 DEG FAHRENHEIT MINIMUM AND 200.0 DEG FAHRENHEIT MAXIMUM |
AKBY | TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
CQYJ | MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
ABHP | OVERALL LENGTH | 1.250 INCHES NOMINAL |
ADAQ | BODY LENGTH | 0.750 INCHES NOMINAL |
CTHF | CONTACT LOAD CURRENT RATING | 2.5 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
AXGY | MOUNTING METHOD | UNTHREADED HOLE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, BOTH POSITIONS MAINTAINED |