Part Number
Definition:
AN ITEM CONSISTING OF INSULATING MATERIAL, WHICH IS SPECIFICALLY DESIGNED TO HAVE FASTENED THEREON, OR ON WHICH ARE FASTENED TERMINAL(S), SUCH AS SCREWS, SOLDER LUGS, SOLDER STUDS, SOLDERLESS CONNECTORS, CLIPS, AND THE LIKE. IT IS USUALLY USED FOR JUNCTIONS OR TERMINATIONS OF WIRE OR CABLE ASSEMBLIES. IT DOES NOT INCLUDE ITEMS AS DEFINED ABOVE WITH PARTS, SUCH AS RESISTORS AND CAPACITORS MOUNTED THEREON. DO NOT USE IF A MORE SPECIFIC NAME EXISTS, SUCH AS FUSEHOLDER; HOLDER, RESISTOR; FANNING STRIP; CONTACT ASSEMBLY, ELECTRICAL; JACK ASSEMBLY, TIP; CHAMBER, CABLE TERMINAL; PANEL (2) (AS MODIFIED); CONNECTOR (AS MODIFIED). EXCLUDES TERMINAL, STUD; TERMINAL, FEEDTHRU, INSULATED; POST, BINDING, ELECTRICAL; AND CHASSIS, ELECTRICAL-ELECTRONIC EQUIPMENT. FOR ITEMS HAVING PRINTED ELECTRICAL CONDUCTOR PATHS, SEE PRINTED WIRING BOARD.
CAGE Information
Code | Company |
---|---|
83330 | DIALIGHT CORPORATION |
Federal Supply Class
Title
LUGS, TERMINALS, AND TERMINAL ST
Inclusions:
INCLUDES BINDING POSTS; BATTERY CLIPS; STUD TERMINALS; TEST CLIPS.
Exclusions:
EXCLUDES CAPS, ELECTRICAL; CLIPS, ELECTRICAL; AND CONTACTS, ELECTRICAL.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABGR | BOARD HEIGHT EXCLUDING TERMINALS | 0.750 INCHES |
ABGR | BOARD HEIGHT EXCLUDING TERMINALS | 0.750 INCHES |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
CRNL | NONFEEDTHRU TERMINAL TYPE | 205 SECOND |
SFTT | SURFACE TREATMENT | TIN TERMINALS |
ABCT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.688 INCHES |
ABDX | DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITY | 0.219 INCHES |
ABGQ | BOARD OVERALL HEIGHT | 0.750 INCHES |
ABCS | TERMINAL ROW QUANTITY | 2 |
CWLG | TERMINAL PATTERN ARRANGEMENT | MULTI-ROW |
ABDU | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.438 INCHES |
CSCS | NONFEEDTHRU TERMINAL QUANTITY | 4 FIRST |
AAMA | MOUNTING HOLE DIAMETER | 0.165 INCHES |
ABDW | DISTANCE FROM BOTTOM EDGE OF TERMINAL BOARD TO CENTER OF MOUNTING HOLE | 0.594 INCHES |
CSCS | NONFEEDTHRU TERMINAL QUANTITY | 4 SECOND |
CRNL | NONFEEDTHRU TERMINAL TYPE | 857 FIRST |
CWLN | TERMINAL DESIGN | NONFEEDTHRU |
MATT | MATERIAL | COPPER ALLOY TERMINALS |
ABCU | DISTANCE BETWEEN TERMINAL ROW CENTERS | 0.625 INCHES |
ABCX | BOARD CONSTRUCTION | HOLLOW CONSTRUCTION WITHOUT INSULATED STRIP |
AAPB | DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 1700.0 |
ABGS | BASE THICKNESS | 0.438 INCHES |
AMPS | CURRENT RATING IN AMPS | 50.0 |
ABGP | BOARD OVERALL WIDTH | 1.812 INCHES |
MATT | MATERIAL | PLASTIC PHENOLIC BOARD |
ABGN | BOARD OVERALL LENGTH | 3.875 INCHES |
ABDV | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.625 INCHES |
AAQL | BODY STYLE | BARRIER TYPE |