Part Number
Definition:
AN ITEM CONSISTING OF INSULATING MATERIAL, WHICH IS SPECIFICALLY DESIGNED TO HAVE FASTENED THEREON, OR ON WHICH ARE FASTENED TERMINAL(S), SUCH AS SCREWS, SOLDER LUGS, SOLDER STUDS, SOLDERLESS CONNECTORS, CLIPS, AND THE LIKE. IT IS USUALLY USED FOR JUNCTIONS OR TERMINATIONS OF WIRE OR CABLE ASSEMBLIES. IT DOES NOT INCLUDE ITEMS AS DEFINED ABOVE WITH PARTS, SUCH AS RESISTORS AND CAPACITORS MOUNTED THEREON. DO NOT USE IF A MORE SPECIFIC NAME EXISTS, SUCH AS FUSEHOLDER; HOLDER, RESISTOR; FANNING STRIP; CONTACT ASSEMBLY, ELECTRICAL; JACK ASSEMBLY, TIP; CHAMBER, CABLE TERMINAL; PANEL (2) (AS MODIFIED); CONNECTOR (AS MODIFIED). EXCLUDES TERMINAL, STUD; TERMINAL, FEEDTHRU, INSULATED; POST, BINDING, ELECTRICAL; AND CHASSIS, ELECTRICAL-ELECTRONIC EQUIPMENT. FOR ITEMS HAVING PRINTED ELECTRICAL CONDUCTOR PATHS, SEE PRINTED WIRING BOARD.
CAGE Information
Code | Company |
---|---|
26405 | MARATHON SPECIAL PRODUCTS CORPORATIO |
Federal Supply Class
Title
LUGS, TERMINALS, AND TERMINAL ST
Inclusions:
INCLUDES BINDING POSTS; BATTERY CLIPS; STUD TERMINALS; TEST CLIPS.
Exclusions:
EXCLUDES CAPS, ELECTRICAL; CLIPS, ELECTRICAL; AND CONTACTS, ELECTRICAL.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABCX | BOARD CONSTRUCTION | SOLID CONSTRUCTION |
ABGR | BOARD HEIGHT EXCLUDING TERMINALS | 0.750 INCHES |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
SFTT | SURFACE TREATMENT | TIN TERMINALS |
ABCT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.688 INCHES |
ABDX | DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITY | 0.219 INCHES |
ABGQ | BOARD OVERALL HEIGHT | 0.750 INCHES |
ABCS | TERMINAL ROW QUANTITY | 2 |
ABDU | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 8.938 INCHES |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | MIL-M-14,TYPE CFG MIL SPEC SINGLE MATERIAL RESPONSE BOARD |
AAMA | MOUNTING HOLE DIAMETER | 0.165 INCHES |
ABGN | BOARD OVERALL LENGTH | 9.375 INCHES |
CWLG | TERMINAL PATTERN ARRANGEMENT | SINGLE ROW |
CQCW | FEEDTHRU CONNECTION END TYPE | F4 SECOND END SINGLE COMBINATION |
ABDW | DISTANCE FROM BOTTOM EDGE OF TERMINAL BOARD TO CENTER OF MOUNTING HOLE | 0.344 INCHES |
ABCU | DISTANCE BETWEEN TERMINAL ROW CENTERS | 0.625 INCHES |
ABGS | BASE THICKNESS | 0.438 INCHES |
CRZR | FEEDTHRU TERMINAL QUANTITY | 12 SINGLE COMBINATION |
ABGP | BOARD OVERALL WIDTH | 1.813 INCHES |
ABDV | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.625 INCHES |
CWLN | TERMINAL DESIGN | FEEDTHRU |
MATT | MATERIAL | PLASTIC PHENOLIC BOARD AND CELLULOSE BOARD |
AAQL | BODY STYLE | BARRIER TYPE |