Part Number
Part Number:
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
CAGE Information
Code | Company |
---|---|
81640 | EATON CORPORATION DBA FLUID POWER DI |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 50.0 AMPERES AC RESISTIVE LOAD AND 50.0 AMPERES DC RESISTIVE LOAD |
AKDX | WINDING QUANTITY | 1 |
CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES AC INDUCTIVE LOAD AND 5.0 AMPERES DC INDUCTIVE LOAD |
CSKP | NONPILE-UP AUXILIARY CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, DOUBLE BREAK, MOMENTARY ACTION AND 1 POLE, SINGLE THROW, NORMALLY OPEN, DOUBLE MAKE, MOMENTARY ACTION |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 25.0 AMPERES AC LAMP LOAD AND 25.0 AMPERES DC LAMP LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 50.0 AMPERES AC INDUCTIVE LOAD AND 50.0 AMPERES DC INDUCTIVE LOAD |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
TTQY | TERMINAL TYPE AND QUANTITY | 8 THREADED STUD ALL FUNCTIONS |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-6106 SPECIFICATION |
APCN | COIL QUANTITY | 1 |
CRXH | TIME DELAY | 0.02 SECONDS MAXIMUM FIXED OPERATE TIME |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 50.0 AMPERES AC MOTOR LOAD AND 50.0 AMPERES DC MOTOR LOAD |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.218 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABMK | OVERALL WIDTH | 2.700 INCHES MAXIMUM |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.188 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CBME | CUBIC MEASURE | 30.694 CUBIC INCHES |
ZZZK | SPECIFICATION/STANDARD DATA | 96906-MS24140 GOVERNMENT STANDARD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
APNQ | ARC QUENCHING METHOD | AIR |
ABKW | OVERALL HEIGHT | 4.010 INCHES MAXIMUM |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 500.0 MILLIAMPERES DC SINGLE WINDING |
APNP | DUTY TYPE | CONTINUOUS |
ABHP | OVERALL LENGTH | 2.835 INCHES MAXIMUM |
CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES AC RESISTIVE LOAD AND 5.0 AMPERES DC RESISTIVE LOAD |
CQYJ | MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
ADTV | CASE MATERIAL | METAL |
CSQC | AUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
CRXH | TIME DELAY | 0.01 SECONDS MAXIMUM FIXED RELEASE TIME |
CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 750.0 MILLIAMPERES AC LAMP LOAD AND 750.0 MILLIAMPERES DC LAMP LOAD |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, DOUBLE MAKE, MOMENTARY ACTION |
APNA | WINDING DC RESISTANCE RATING | 78.0 OHMS NOMINAL SINGLE WINDING |