CIRCUIT BREAKER

Definition:

A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.

CAGE Information

Code Company
A1997 ELETTRONICA SPA

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 115.0 SINGLE LOCATION
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT SINGLE LOCATION
TTQY TERMINAL TYPE AND QUANTITY 2 SCREW
AXHR MOUNTING FACILITY TYPE AND QUANTITY 1 THREADED BUSHING
AAQL BODY STYLE SINGLE POLE TYPE
THSD THREAD SERIES DESIGNATOR UN
ADAT BODY WIDTH 0.562 INCHES NOMINAL
CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
CRCF TRIP RELEASE AMBIENT TEMP RATING 25.0 DEG CELSIUS MAXIMUM SINGLE LOCATION
ABXD BUSHING LENGTH 0.359 INCHES NOMINAL
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 800.0 AC SINGLE LOCATION AND 800.0 DC SINGLE LOCATION
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 2.0 AMPERES AC SINGLE LOCATION AND 2.0 AMPERES DC SINGLE LOCATION
AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 1.302 INCHES NOMINAL
ADTV CASE MATERIAL PLASTIC
AKPX POLE QUANTITY 1
CPRQ RESET METHOD MANUAL
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 0.593 INCHES NOMINAL
CPRJ TRIP RELEASE METHOD THERMAL SINGLE LOCATION
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 8.500 NOMINAL AT 200 PCT SINGLE LOCATION
CPRT MANUAL ACTUATOR TYPE AND QUANTITY 1 PUSH-PULL
CPRW ACTUATOR FUNCTION TRIP-RESET
CPRX ACTUATOR POSITION DESIGNATION AT POLE ONE
CQJX NOMINAL THREAD SIZE 0.437 INCHES
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 120.0 AC SINGLE LOCATION AND 30.0 DC SINGLE LOCATION
FREQ FREQUENCY IN HERTZ 400.0 SINGLE LOCATION
CMLP THREAD QUANTITY PER INCH 32
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY SINGLE LOCATION
ADAQ BODY LENGTH 0.750 INCHES NOMINAL

Similar Parts

605-101-301 , 605101301 , 5925-00-818-3420 , 5925008183420 , 008183420