Part Number
Definition:
AN ITEM HAVING EITHER A SINGLE TAPPED WINDING (AUTOTRANSFORMER TYPE), OR TWO OR MORE WINDINGS DESIGNED TO FURNISH INDUCTIVE REACTANCE AND/OR TRANSFER ELECTRICAL ENERGY IN CIRCUITS BY MEANS OF A MAGNETIC FIELD. IT IS SO DESIGNED THAT ITS ENTIRE INTENDED RANGE OF OPERATIONS IS ABOVE 20 KILOHERTZ (KILOCYCLES). THE MINIMUM VALUE MAY EXTEND INTO THE AUDIO FREQUENCY RANGE (BELOW 20 KILOHERTZ). IT MAY INCLUDE INTEGRAL CAPACITORS, COILS, RESISTORS, AND ADJUSTABLE TUNING CORES. FOR ITEMS HAVING ONLY TWO ACTIVE TERMINALS SEE COIL, RADIO FREQUENCY. INCLUDES TYPES HAVING WINDINGS WHICH MAY BE MOVED WITH RESPECT TO EACH OTHER. EXCLUDES TRANSFORMER, DISCRIMINATOR.
CAGE Information
Code | Company |
---|---|
14590 | VERIDIAN ENGINEERING INC |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CQLC | WINDING TAP LOCATION (NON-CORE) | TAP W/O CENTER TAP SINGLE COMPONENT SINGLE PRIMARY |
CQNJ | TAP LOCATION IN TURNS (NON-CORE) | 30.000 SINGLE COMPONENT 1ST SECONDARY |
CQPZ | WINDING CONDUCTOR SIZE | 0.00397 INCHES AMERICAN WIRE GAGE SINGLE COMPONENT 1ST SECONDARY |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
BKPL | RATING METHOD | WINDING TURNS SINGLE COMPONENT ALL SECONDARY |
CQPZ | WINDING CONDUCTOR SIZE | 0.00708 INCHES AMERICAN WIRE GAGE SINGLE COMPONENT 2ND SECONDARY |
CQLC | WINDING TAP LOCATION (NON-CORE) | TAP W/O CENTER TAP SINGLE COMPONENT 1ST SECONDARY |
CQNJ | TAP LOCATION IN TURNS (NON-CORE) | 14.000 SINGLE COMPONENT SINGLE PRIMARY |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
TTQY | TERMINAL TYPE AND QUANTITY | 8 PIN |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
ABHY | TURN QUANTITY | 188 SINGLE COMPONENT 1ST SECONDARY |
ABHY | TURN QUANTITY | 31 SINGLE COMPONENT 2ND SECONDARY |
CQPZ | WINDING CONDUCTOR SIZE | 0.01790 INCHES AMERICAN WIRE GAGE SINGLE COMPONENT SINGLE PRIMARY |
BKPL | RATING METHOD | WINDING TURNS SINGLE COMPONENT SINGLE PRIMARY |
ABHY | TURN QUANTITY | 50 SINGLE COMPONENT SINGLE PRIMARY |