Part Number
Part Number:
NSN:
NIIN:
Item Name:
FAN , CENTRIFUGAL
Definition:
A NONPOSITIVE DISPLACEMENT MECHANICAL DEVICE HAVING A CENTRIFUGAL FAN IMPELLER INCLOSED WITHIN A HOUSING. IT IS DESIGNED TO MOVE AIR OR GAS OVER A WIDE RANGE OF VOLUMES AND PRESSURES. THE AIR OR GAS IS DRAWN IN AXIALLY AND DISCHARGED RADIALLY OR DRAWN IN RADIALLY AND DISCHARGED AXIALLY BY CENTRIFUGAL FORCE THROUGH AN OUTLET IN THE HOUSING.
CAGE Information
Code | Company |
---|---|
70210 | HONEYWELL INTERNATIONAL INC. DBA HON |
Federal Supply Class
Title
FANS, AIR CIRCULATORS, AND BLOWE
Inclusions:
INCLUDES WALL TYPE FANS; PEDESTAL TYPE FANS; HOUSEHOLD TYPE AND ATTIC TYPE EXHAUST FANS; FLOOR FANS; FORGED DRAFT EXHAUST AND DISPOSAL KITS; FANS, AIR CIRCULATORS, AND BLOWER EQUIPMENT, WHETHER DESIGNATED AS "INDUSTRIAL" OR "NONINDUSTRIAL" BY APPLICATION AND/OR USE.
Exclusions:
EXCLUDES COMBINATION HEATER-FANS (FSC 4520).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CRWJ | OUTLET LOCATION | TOP |
AKCV | DRIVE TYPE | DIRECT |
CQKX | AIR FLOW RATE | 700.0 CUBIC FEET PER MINUTE NOMINAL |
NMBR | QUANTITY | 1 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 10 BOLT |
TEST | TEST DATA DOCUMENT | 02731-7-113320000 SPECIFICATION |
AJLY | STATIC PRESSURE AT SPECIFIED AIR FLOW RATE | 3.0 INCHES OF WATER |
CXCB | DISCHARGE DIRECTION | ANGULAR UP |
AYSY | ROTATION DIRECTION FOR WHICH DESIGNED | CLOCKWISE |