National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
STARTER , MOTOR
Definition:
A DEVICE PRIMARILY DESIGNED TO CONTROL THE SUPPLY CIRCUIT(S) OF A MOTOR IN ORDER TO ACCELERATE THE MOTOR FROM REST TO NORMAL SPEED. INCLUDES MANUAL STARTERS WITH OVERLOAD PROTECTION AND MANUAL, AUTOMATIC OR SEMIAUTOMATIC STARTERS CONSISTING OF COMBINATIONS OF ITEMS SUCH AS RELAYS, RESISTORS, SWITCHES, CIRCUIT BREAKERS, ETC. EXCLUDES RELAY-SWITCH; CIRCUIT BREAKER; SWITCH (AS MODIFIED) AND RELAY (AS MODIFIED). FOR DEVICES, WHICH IN ADDITION TO STARTING AND STOPPING, REVERSE, SELECT AND/OR REGULATE THE SPEED OF A MOTOR, SEE CONTROLLER (AS MODIFIED).
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
22111-1 | 63743 | A | 3 | 2 | X | XX | ||
22111 | 63743 | A | 5 | 9 | 1 | HD | ||
S6307-3194497 | 80064 | A | 5 | 9 | 1 | HD |
CAGE Information
Code | Company |
---|---|
63743 | WARD LEONARD ELECTRIC COMPANY INC. |
80064 | NAVAL SHIP SYSTEMS COMMAND |
Federal Supply Class
Title
ELECTRICAL CONTROL EQUIPMENT
Inclusions:
INCLUDES CONTACTORS; MOTOR CONTROLLERS; POWER SERVOMECHANISMS; SWITCHGEAR; VOLTAGE REGULATORS.
Exclusions:
EXCLUDES AUTOMATIC PILOT MECHANISMS; RELAYS; RESISTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AQZF | CONTROL TYPE | REMOTE |
AGLD | PERFORMANCE TYPE | SEMIAUTOMATIC |
ANCQ | FULL VOLTAGE RESTORING METHOD | CURRENT LIMIT ACCELERATION |
ANCN | OPERATING VOLTAGE CHARACTERISTIC | REDUCED |
ABKW | OVERALL HEIGHT | 15.750 INCHES NOMINAL |
ANCP | VOLTAGE REDUCTION METHOD | RESISTOR |
ALGC | MOUNTING CONFIGURATION | FOUR 9/16 IN. DIA MTG HOLES ON 27 IN. BY 13-1/2 IN. MTG CENTERS |
ANDX | AMBIENT TEMP | 50.000 DEG CELSIUS |
ANCY | HORSEPOWER RATING | 15.000 |
ANDE | ACTUATOR VOLTAGE | 230.0 DC |
CBBL | FEATURES PROVIDED | CIRCUIT PROTECTION FUSE |
ANPZ | INCLOSURE FEATURE | DRIPPROOF |
AGUE | FUSE ACCOMMODATION QUANTITY | 1 |
AKPS | DUTY CYCLE | CONTINUOUS |
AFLW | ACTUATION METHOD | MAGNETIC |
ACUT | DIRECT CURRENT RATING IN AMPS | 56.0 |
ACYR | DC VOLTAGE RATING | 230.0 VOLTS NOMINAL |
ABMK | OVERALL WIDTH | 17.125 INCHES NOMINAL |
ABBB | SPEED ADJUSTMENTS | SINGLE SPEED |
ANDW | LOAD PROTECTION TYPE | OVERLOAD AND UNDERVOLTAGE |
ABHP | OVERALL LENGTH | 28.500 INCHES NOMINAL |