National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
STARTER , MOTOR
Definition:
A DEVICE PRIMARILY DESIGNED TO CONTROL THE SUPPLY CIRCUIT(S) OF A MOTOR IN ORDER TO ACCELERATE THE MOTOR FROM REST TO NORMAL SPEED. INCLUDES MANUAL STARTERS WITH OVERLOAD PROTECTION AND MANUAL, AUTOMATIC OR SEMIAUTOMATIC STARTERS CONSISTING OF COMBINATIONS OF ITEMS SUCH AS RELAYS, RESISTORS, SWITCHES, CIRCUIT BREAKERS, ETC. EXCLUDES RELAY-SWITCH; CIRCUIT BREAKER; SWITCH (AS MODIFIED) AND RELAY (AS MODIFIED). FOR DEVICES, WHICH IN ADDITION TO STARTING AND STOPPING, REVERSE, SELECT AND/OR REGULATE THE SPEED OF A MOTOR, SEE CONTROLLER (AS MODIFIED).
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
215-108-010 | 6Z538 | A | D | 9 | 2 | ZZ | ||
215-108-013 REV B | 6Z538 | A | D | 9 | 2 | ZZ | ||
215-108-010 REV B | 6Z538 | A | 3 | 2 | 2 | ZZ | ||
PL215-108-010 REV B | 6Z538 | A | 3 | 2 | 4 | ZZ | ||
TYPE 13A1 | 6Z538 | A | 5 | 2 | 2 | ZZ |
CAGE Information
Code | Company |
---|---|
6Z538 | CAROLINA POWER SYSTEMS OF SUMTER INC |
Federal Supply Class
Title
ELECTRICAL CONTROL EQUIPMENT
Inclusions:
INCLUDES CONTACTORS; MOTOR CONTROLLERS; POWER SERVOMECHANISMS; SWITCHGEAR; VOLTAGE REGULATORS.
Exclusions:
EXCLUDES AUTOMATIC PILOT MECHANISMS; RELAYS; RESISTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ACZB | FREQUENCY RATING | 60.0 HERTZ MAXIMUM |
FREQ | FREQUENCY IN HERTZ | 60.0 |
AQZF | CONTROL TYPE | LOCAL OR REMOTE |
ABMK | OVERALL WIDTH | 12.120 INCHES NOMINAL |
AGAV | END ITEM IDENTIFICATION | CONTROLLER,AC TYPE 13A1 |
CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | (INAVY)CONTROLLER, MOTOR;(DRAWING)MOTOR CONTROLLER ES-108 FAN MOTOR ASSY(215-108-010) |
ACYN | AC VOLTAGE RATING | 440.0 VOLTS NOMINAL |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | DRIPPROOF |
ANDX | AMBIENT TEMP | 50.0 DEG CELSIUS |
AGLD | PERFORMANCE TYPE | MANUAL |
ANCY | HORSEPOWER RATING | 10.000 |
FAAZ | PHASE | THREE |
ANDE | ACTUATOR VOLTAGE | 440.0 AC |
CBBL | FEATURES PROVIDED | CIRCUIT PROTECTION FUSE |
ANPZ | INCLOSURE FEATURE | DRIPPROOF |
AKPS | DUTY CYCLE | CONTINUOUS |
ANDG | FUSE CURRENT RATING IN AMPS | 10.0 |
AFLW | ACTUATION METHOD | MAGNETIC |
ANDW | LOAD PROTECTION TYPE | OVERLOAD |
ANQC | NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION STANDARDS DESIGN | NOT DESIGNED PER NEMA STD |
AGUE | FUSE ACCOMMODATION QUANTITY | 2 |
ANCN | OPERATING VOLTAGE CHARACTERISTIC | FULL |
ABKW | OVERALL HEIGHT | 18.120 INCHES NOMINAL |