Item Name:
PANEL , POWER DISTRIBUTION
Definition:
A PANEL DESIGNED FOR CONNECTING, DISCONNECTING AND PROTECTING POWER LINE FEEDERS AND/OR DIRECT CONTROL OF SPECIFIC ELECTRIC DEVICES SUCH AS LIGHTS, MOTORS, ELECTRONIC EQUIPMENT, ETC. SEE ALSO FUSE BOX; SWITCH BOX; DISTRIBUTION BOX; AND PANEL, POWER BUS, CIRCUIT BREAKER.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
6002625 | 80091 | A | 3 | 1 | 1 | JN | ||
MIL-P-29183 | 81349 | M | 4 | 1 | 3 | JN |
CAGE Information
Code | Company |
---|---|
80091 | NAVAL FACILITIES ENGINEERING COMMAND |
81349 | MILITARY SPECIFICATIONS PROMULGATED |
Federal Supply Class
Title
ELECTRICAL CONTROL EQUIPMENT
Inclusions:
INCLUDES CONTACTORS; MOTOR CONTROLLERS; POWER SERVOMECHANISMS; SWITCHGEAR; VOLTAGE REGULATORS.
Exclusions:
EXCLUDES AUTOMATIC PILOT MECHANISMS; RELAYS; RESISTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABHP | OVERALL LENGTH | 84.000 INCHES MAXIMUM |
ABHP | OVERALL LENGTH | 84.000 INCHES MAXIMUM |
APPY | INPUT FREQUENCY IN HERTZ | 60.0 |
APNX | INPUT VOLTAGE RATING | 120.0 AC POUNDS PER HOUR DRY AND 480.0 AC POUNDS PER HOUR WITH RETAINING CHAIN |
APNW | ELECTRICAL INPUT QUANTITY | 1 |
FEAT | SPECIAL FEATURES | BPANELBOARD ARRANGED IN HORIZONTAL CONFIGURATION W/ENCLOSURE BACK AS BOTTOM SIDE AND INCLUDE HINGED COVER ON TOPSIDE,WEATHERPROOFED,CIRCUIT BREAKERS TO BE 3-POLE W/INTERRUPTING RATINGSAT 480V AC IN ACCORDANCE W/FED-SPEC W-C-375A AMEND 4,BE CLASSES AND TRIP RATINGS CONNECTED TO 3-PHASE,1200AMPERE BUS BAR,CL 2F 100 AMP TRIP-2 EA,CL 3B 225 AMP TRIP-6 EA,CL 4B 400 AMP NON-AUTOMATIC TRIP-4 EA,CONDUIT BUSHINGS TO BE TWO-PIECE INSULATING CONFORMING TO TYPE 3,CL 1,KIND R,FED-SPEC W-C-408B IN SIZES AND QUANTITIES,2 IN-2 EA F/10 AMP CIRCUIT BREAKER CONDUCTOR,3 IN-6 EA F/225 AMP CIRCUIT BREAKER CONDUCTOR,4 IN-4 EA F/400 AMP CIRCUITBREAKER CONDUCTOR,CONDUIT BUSHINGS INSTALLED IN ENCLOSURE BOTTOM SIDE IN RELATIVE LOCATION TO CIRCUIT BREAKERS THEY ARE TO BE UTILIZED,1 GROUND TERMINAL W/SOLDERLESS LUG,SOLDERLESS LUG SHALL BE COMPATIBLE W/ALUMINUM AND COPPER AND HAVE THE CAPACITY F/1 NO. 6-AWG COPPER CONDUCTOR,CONFORMS TO PORTA-POWER PAC INC,DWG NO. 105100 OR EQUAL |
FAAZ | PHASE | THREE |
ANJG | PANEL MATERIAL | ALUMINUM |
ABMK | OVERALL WIDTH | 36.000 INCHES MAXIMUM |
ANPM | INPUT PHASE | THREE |
ZZZY | REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | AS MODIFIED BY CONFIGURATION OF PANELBOARD |
APNZ | ELECTRICAL OUTPUT QUANTITY | 6 |
ANPZ | INCLOSURE FEATURE | WATERPROOF |
APCA | PANEL QUANTITY | 1 |
ANSQ | OUTPUT FREQUENCY RATING | 60 HERTZ |
APPA | OUTPUT VOLTAGE RATING | 120.0 AC VOLTS MINIMUM AND 480.0 AC VOLTS MAXIMUM |
ADJH | MOUNTING METHOD | FLOOR |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-P-29183 GOVERNMENT SPECIFICATION |
ABKW | OVERALL HEIGHT | 36.000 INCHES MAXIMUM |
ZZZT | NONDEFINITIVE SPEC/STD DATA | III TYPE AND 3 CLASS |