Follow Us on Google+

Request A Price Quote:

National Stock Number (NSN) Output Data

NSN:
NIIN:
Item Name:
STARTER , MOTOR

Definition:

A DEVICE PRIMARILY DESIGNED TO CONTROL THE SUPPLY CIRCUIT(S) OF A MOTOR IN ORDER TO ACCELERATE THE MOTOR FROM REST TO NORMAL SPEED. INCLUDES MANUAL STARTERS WITH OVERLOAD PROTECTION AND MANUAL, AUTOMATIC OR SEMIAUTOMATIC STARTERS CONSISTING OF COMBINATIONS OF ITEMS SUCH AS RELAYS, RESISTORS, SWITCHES, CIRCUIT BREAKERS, ETC. EXCLUDES RELAY-SWITCH; CIRCUIT BREAKER; SWITCH (AS MODIFIED) AND RELAY (AS MODIFIED). FOR DEVICES, WHICH IN ADDITION TO STARTING AND STOPPING, REVERSE, SELECT AND/OR REGULATE THE SPEED OF A MOTOR, SEE CONTROLLER (AS MODIFIED).

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
F942-1-53M5PC1T013 15605 A 3 2 5 XX
6307-3124996PC1T013 80064 A 3 2 5 XX
MILC2174SIZE1SERVICEA 81349 M 4 1 X XX
6942ED1073 15605 A 3 2 5 XX
A6942CD57PARAGRAPHESE1 15605 A 3 2 5 XX
3801-1297708PARAGRAPHESH1 80064 A 3 2 5 XX

CAGE Information

Code Company
15605 EATON CORP OPNS & TECHNICAL CENTER
80064 NAVAL SHIP SYSTEMS COMMAND
81349 MILITARY SPECIFICATIONS PROMULGATED

Federal Supply Class

Title

ELECTRICAL CONTROL EQUIPMENT

Inclusions:

INCLUDES CONTACTORS; MOTOR CONTROLLERS; POWER SERVOMECHANISMS; SWITCHGEAR; VOLTAGE REGULATORS.

Exclusions:

EXCLUDES AUTOMATIC PILOT MECHANISMS; RELAYS; RESISTORS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AGLD PERFORMANCE TYPE SEMIAUTOMATIC
ANCQ FULL VOLTAGE RESTORING METHOD CURRENT LIMIT ACCELERATION
ACUT DIRECT CURRENT RATING IN AMPS 25.0
ANCN OPERATING VOLTAGE CHARACTERISTIC REDUCED
ANCP VOLTAGE REDUCTION METHOD RESISTOR
AQZF CONTROL TYPE LOCAL OR REMOTE
ABHP OVERALL LENGTH 15.500 INCHES NOMINAL
ANDX AMBIENT TEMP 50.0 DEG CELSIUS
ALGC MOUNTING CONFIGURATION SIX 21/32 IN. DIA MTG HOLES IN 2 ROWS 3 HOLES IN EA ROW,ROWS 20 IN. APART HOLES SPACED 5-3/4 IN. C TO C
ABKW OVERALL HEIGHT 23.000 INCHES NOMINAL
ZZZT NONDEFINITIVE SPEC/STD DATA 1 SIZE AND A SERVICE
CBBL FEATURES PROVIDED CIRCUIT PROTECTION FUSE
ANCY HORSEPOWER RATING 1.000
ANPZ INCLOSURE FEATURE DRIPPROOF
ANDE ACTUATOR VOLTAGE 170.0 DC AND 345.0 DC
AGUE FUSE ACCOMMODATION QUANTITY 1
AKPS DUTY CYCLE CONTINUOUS
ABMK OVERALL WIDTH 10.000 INCHES NOMINAL
AFLW ACTUATION METHOD MAGNETIC
ANDW LOAD PROTECTION TYPE OVERLOAD
ALCD USAGE DESIGN U/W RHEOSTAT
ANRK SWITCH FUNCTIONAL POSITIONS START AND STOP
ABBB SPEED ADJUSTMENTS SINGLE SPEED
ACYR DC VOLTAGE RATING 175.0 VOLTS MINIMUM AND 345.0 VOLTS MAXIMUM

Similar Parts

6942ED1073 , 6942ED1073 , 6110-00-500-0749 , 6110005000749 , 005000749 , F942-1-53M5PC1T013 , 6307-3124996PC1T013 , MILC2174SIZE1SERVICEA , 6942ED1073 , A6942CD57PARAGRAPHESE1 , 3801-1297708PARAGRAPHESH1 ,