National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
STARTER , MOTOR
Definition:
A DEVICE PRIMARILY DESIGNED TO CONTROL THE SUPPLY CIRCUIT(S) OF A MOTOR IN ORDER TO ACCELERATE THE MOTOR FROM REST TO NORMAL SPEED. INCLUDES MANUAL STARTERS WITH OVERLOAD PROTECTION AND MANUAL, AUTOMATIC OR SEMIAUTOMATIC STARTERS CONSISTING OF COMBINATIONS OF ITEMS SUCH AS RELAYS, RESISTORS, SWITCHES, CIRCUIT BREAKERS, ETC. EXCLUDES RELAY-SWITCH; CIRCUIT BREAKER; SWITCH (AS MODIFIED) AND RELAY (AS MODIFIED). FOR DEVICES, WHICH IN ADDITION TO STARTING AND STOPPING, REVERSE, SELECT AND/OR REGULATE THE SPEED OF A MOTOR, SEE CONTROLLER (AS MODIFIED).
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
509-TAH | 01121 | A | 3 | 2 | E | CX | ||
709-TAH | 01121 | A | 5 | 9 | E | CX |
CAGE Information
Code | Company |
---|---|
01121 | ROCKWELL AUTOMATION INC. |
Federal Supply Class
Title
ELECTRICAL CONTROL EQUIPMENT
Inclusions:
INCLUDES CONTACTORS; MOTOR CONTROLLERS; POWER SERVOMECHANISMS; SWITCHGEAR; VOLTAGE REGULATORS.
Exclusions:
EXCLUDES AUTOMATIC PILOT MECHANISMS; RELAYS; RESISTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AQZF | CONTROL TYPE | REMOTE |
ANRK | SWITCH FUNCTIONAL POSITIONS | RESET |
AGLD | PERFORMANCE TYPE | SEMIAUTOMATIC |
FREQ | FREQUENCY IN HERTZ | 60.0 |
ABHP | OVERALL LENGTH | 9.188 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 4.625 INCHES NOMINAL |
ANDX | AMBIENT TEMP | 50.0 DEG CELSIUS |
ABMK | OVERALL WIDTH | 6.312 INCHES NOMINAL |
ACYN | AC VOLTAGE RATING | 200.0 VOLTS NOMINAL |
FAAZ | PHASE | THREE |
ANQC | NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION STANDARDS DESIGN | DESIGNED PER NEMA STD |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL |
AJXE | SIZE DESIGNATOR | 00 |
AKPS | DUTY CYCLE | CONTINUOUS |
AFLW | ACTUATION METHOD | MAGNETIC |
ANDW | LOAD PROTECTION TYPE | OVERLOAD |
ANCN | OPERATING VOLTAGE CHARACTERISTIC | FULL |
ANCY | HORSEPOWER RATING | 1.500 |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | GENERAL PURPOSE-NEMA TYPE 1 |
ALGC | MOUNTING CONFIGURATION | FIVE MTG HOLES,ONE HOLE 0.250 IN. TO LEFT OF CENTER LINE AT TOP,FOUR MTG HOLES ON 6.875 IN. BY5.000 IN. MTG CENTERS |
ANDE | ACTUATOR VOLTAGE | 208.0 AC |