National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
STARTER , MOTOR
Definition:
A DEVICE PRIMARILY DESIGNED TO CONTROL THE SUPPLY CIRCUIT(S) OF A MOTOR IN ORDER TO ACCELERATE THE MOTOR FROM REST TO NORMAL SPEED. INCLUDES MANUAL STARTERS WITH OVERLOAD PROTECTION AND MANUAL, AUTOMATIC OR SEMIAUTOMATIC STARTERS CONSISTING OF COMBINATIONS OF ITEMS SUCH AS RELAYS, RESISTORS, SWITCHES, CIRCUIT BREAKERS, ETC. EXCLUDES RELAY-SWITCH; CIRCUIT BREAKER; SWITCH (AS MODIFIED) AND RELAY (AS MODIFIED). FOR DEVICES, WHICH IN ADDITION TO STARTING AND STOPPING, REVERSE, SELECT AND/OR REGULATE THE SPEED OF A MOTOR, SEE CONTROLLER (AS MODIFIED).
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
6942ED1478 | 27192 | A | 3 | 2 | A | CX | ||
942-1-160M9 | 27192 | A | 5 | 2 | A | CX |
CAGE Information
Code | Company |
---|---|
27192 | DRS POWER & CONTROL TECHNOLOGIES INC |
Federal Supply Class
Title
ELECTRICAL CONTROL EQUIPMENT
Inclusions:
INCLUDES CONTACTORS; MOTOR CONTROLLERS; POWER SERVOMECHANISMS; SWITCHGEAR; VOLTAGE REGULATORS.
Exclusions:
EXCLUDES AUTOMATIC PILOT MECHANISMS; RELAYS; RESISTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AQZF | CONTROL TYPE | LOCAL |
AGLD | PERFORMANCE TYPE | SEMIAUTOMATIC |
ANCN | OPERATING VOLTAGE CHARACTERISTIC | REDUCED |
ANCP | VOLTAGE REDUCTION METHOD | RESISTOR |
ANCQ | FULL VOLTAGE RESTORING METHOD | TIME LIMIT ACCELERATION |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | DRIPPROOF |
ALGC | MOUNTING CONFIGURATION | FOUR 21/32 IN. DIA HOLES; RECTANGULAR PATTERN; 15-1/2 IN. BY 40-3/8 IN. CENTERS |
ANDX | AMBIENT TEMP | 50.0 DEG CELSIUS |
ANCY | HORSEPOWER RATING | 70.000 |
ABHP | OVERALL LENGTH | 42.100 INCHES NOMINAL |
CBBL | FEATURES PROVIDED | CIRCUIT PROTECTION FUSE |
ANQC | NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION STANDARDS DESIGN | DESIGNED PER NEMA STD |
ABKW | OVERALL HEIGHT | 14.000 INCHES NOMINAL |
ABBB | SPEED ADJUSTMENTS | 0 TO FULL SPEED |
ANPZ | INCLOSURE FEATURE | DRIPPROOF |
ABMK | OVERALL WIDTH | 19.100 INCHES NOMINAL |
AKPS | DUTY CYCLE | CONTINUOUS |
ANDG | FUSE CURRENT RATING IN AMPS | 10.0 |
AJXE | SIZE DESIGNATOR | 5 |
AFLW | ACTUATION METHOD | MAGNETIC |
ANDW | LOAD PROTECTION TYPE | UNDERVOLTAGE |
ANRK | SWITCH FUNCTIONAL POSITIONS | START AND STOP |
AGUE | FUSE ACCOMMODATION QUANTITY | 2 |
ANDE | ACTUATOR VOLTAGE | 67.0 DC AND 250.0 DC |
ACYR | DC VOLTAGE RATING | 250.0 VOLTS NOMINAL |