National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
STARTER , MOTOR
Definition:
A DEVICE PRIMARILY DESIGNED TO CONTROL THE SUPPLY CIRCUIT(S) OF A MOTOR IN ORDER TO ACCELERATE THE MOTOR FROM REST TO NORMAL SPEED. INCLUDES MANUAL STARTERS WITH OVERLOAD PROTECTION AND MANUAL, AUTOMATIC OR SEMIAUTOMATIC STARTERS CONSISTING OF COMBINATIONS OF ITEMS SUCH AS RELAYS, RESISTORS, SWITCHES, CIRCUIT BREAKERS, ETC. EXCLUDES RELAY-SWITCH; CIRCUIT BREAKER; SWITCH (AS MODIFIED) AND RELAY (AS MODIFIED). FOR DEVICES, WHICH IN ADDITION TO STARTING AND STOPPING, REVERSE, SELECT AND/OR REGULATE THE SPEED OF A MOTOR, SEE CONTROLLER (AS MODIFIED).
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
D-WK-774-22 | 63705 | A | 3 | 2 | A | ZZ |
CAGE Information
Code | Company |
---|---|
63705 | WALZ AND KRENZER INC |
Federal Supply Class
Title
ELECTRICAL CONTROL EQUIPMENT
Inclusions:
INCLUDES CONTACTORS; MOTOR CONTROLLERS; POWER SERVOMECHANISMS; SWITCHGEAR; VOLTAGE REGULATORS.
Exclusions:
EXCLUDES AUTOMATIC PILOT MECHANISMS; RELAYS; RESISTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ALGC | MOUNTING CONFIGURATION | TWO HOLES AT THE TOP 9.500 APART, 25.250 FROM THE BOTTOM , TWO SLOTS 9.500 APART. |
AQZF | CONTROL TYPE | LOCAL |
ANCQ | FULL VOLTAGE RESTORING METHOD | CURRENT LIMIT ACCELERATION |
ANCN | OPERATING VOLTAGE CHARACTERISTIC | REDUCED |
ABHP | OVERALL LENGTH | 25.250 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 7.156 INCHES NOMINAL |
AGLD | PERFORMANCE TYPE | AUTOMATIC |
AJXE | SIZE DESIGNATOR | 4 |
ANDG | FUSE CURRENT RATING IN AMPS | 15.0 |
FAAZ | PHASE | THREE |
ANQC | NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION STANDARDS DESIGN | DESIGNED PER NEMA STD |
ANDE | ACTUATOR VOLTAGE | 110.0 AC |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL |
AKPS | DUTY CYCLE | CONTINUOUS |
ABMK | OVERALL WIDTH | 25.250 INCHES NOMINAL |
CBBL | FEATURES PROVIDED | CIRCUIT PROTECTION FUSE AND ACCESSORY LOCATION INTERNAL |
AFLW | ACTUATION METHOD | MAGNETIC |
ANDW | LOAD PROTECTION TYPE | OVERLOAD |
ANCY | HORSEPOWER RATING | 3.000 |
AKVZ | ACCESSORY IDENTIFYING NUMBER | D-WK-774-22 PART NO. |
AGUE | FUSE ACCOMMODATION QUANTITY | 2 |
ABBB | SPEED ADJUSTMENTS | SINGLE SPEED |
ANCP | VOLTAGE REDUCTION METHOD | AUTOTRANSFORMER |
AKVY | ACCESSORY CONTROLLING AGENCY | WALZ AND KRENZER INC. |