National Stock Number (NSN) Output Data

NSN:
NIIN:
Item Name:
TRANSFORMER , POWER

Definition:

A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
CTR015 1GD22 A 3 2 4 9Z
713.1202 0FZR3 F 5 9 4 9Z

CAGE Information

Code Company
0FZR3 TOROID CORP OF MARYLAND
1GD22 GENERAL DYNAMICS SATCOM TECHNOLOGIES

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
CWJS WINDING OPERATING VOLTAGE 117.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY
AKNA INCLOSURE TYPE FULLY INCLOSED
FEAT SPECIAL FEATURES SUPPLY VOLTAGE RANGE IS PLUS OR MINUS 10 PERCENT; PRIMARIES ARE INSIDE SLEEVE AND MUST BE CONNECTED TOGETHER IN SERIES OR PARALLEL; PRIMARY LEAD WIRES ARE MAGNET WIRE SELF-LEADS, 24 GAUGE, 8.000 IN. LENGTH NOMINAL; SECONDARY LEAD WIRES ARE MULTI-STRANDED, 22 GAUGE, 8.000 IN. LENGTH NOMINAL; CORE NO. 900140, NO-LOAD LOSS EQUALS 0.9 WATT , NO-LOAD AMPERAGE EQUALS 8.7 MILLIAMPS; UL RECOGNIZED TO UL 1411 AND CSA CERTIFIED TO CSA C22.2, NO. 66
CBBL FEATURES PROVIDED PROTECTIVE COVER AND COLOR CODED LEAD AND SPECIAL MARKING
TTQY TERMINAL TYPE AND QUANTITY 4 WIRE LEAD
PKWT UNPACKAGED UNIT WEIGHT (NON-CORE) 3.000 POUNDS
AARG RELIABILITY INDICATOR NOT ESTABLISHED
CRBZ WINDING OPERATING CURRENT 0.6 AMPERES NOMINAL B SINGLE COMPONENT SINGLE SECONDARY
ADAR BODY OUTSIDE DIAMETER 3.900 INCHES NOMINAL
CRBZ WINDING OPERATING CURRENT 0.7 AMPERES NOMINAL B AND BETTER SINGLE COMPONENT SINGLE PRIMARY AND 1.4 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE PRIMARY
ACZB FREQUENCY RATING 50.0 HERTZ NOMINAL SINGLE COMPONENT OR 60.0 HERTZ NOMINAL SINGLE COMPONENT
AEHZ MAXIMUM OPERATING TEMP 65.0 DEG CELSIUS
AXGY MOUNTING METHOD UNTHREADED HOLE SINGLE GROUP
CWJS WINDING OPERATING VOLTAGE 117.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
ACZF MAXIMUM TRANSFORMER POWER RATING 150.0 VOLT-AMPERE SINGLE COMPONENT
ABTB MOUNTING HOLE DIAMETER 0.250 INCHES NOMINAL SINGLE GROUP
ADAU BODY HEIGHT 1.900 INCHES NOMINAL

Similar Parts