Part Number
Part Number:
NSN:
NIIN:
Item Name:
TRANSFORMER , CURRENT
Definition:
AN ITEM CONSISTING OF ONE OR MORE WINDINGS, DESIGNED TO BE PLACED NEAR OR CONNECTED IN SERIES WITH AN ALTERNATING CURRENT POWER LINE TO MEASURE THE CURRENT PASSING THROUGH THE LINE BY MEANS OF A METER; OR TO CONTROL THE CURRENT PASSING THROUGH THE LINE BY MEANS OF A CONTROL DEVICE. EXCLUDES TRANSFORMER, POWER, CURRENT REGULATING.
CAGE Information
Code | Company |
---|---|
53711 | NAVAL SEA SYSTEMS COMMAND |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
TTQY | TERMINAL TYPE AND QUANTITY | 4 TURRET |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
ACZB | FREQUENCY RATING | 100.0 KILOHERTZ NOMINAL SINGLE COMPONENT |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 1.57 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE PRIMARY |
ABTB | MOUNTING HOLE DIAMETER | 0.086 INCHES MINIMUM SINGLE GROUP AND 0.106 INCHES MAXIMUM SINGLE GROUP |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
AKPV | MOUNTING FACILITY QUANTITY | 1 SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 2.80 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 0.1 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE SECONDARY |
ADAQ | BODY LENGTH | 0.420 INCHES MAXIMUM |
CWJS | WINDING OPERATING VOLTAGE | 0.20 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
ADAR | BODY OUTSIDE DIAMETER | 0.760 INCHES MAXIMUM |