National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
CABLE , SPECIAL PURPOSE , ELECTRICAL
Definition:
TWO OR MORE INDIVIDUALLY INSULATED CONDUCTORS (SOLID OR STRANDED) CONTAINED IN A COMMON COVERING, OR TWO OR MORE INDIVIDUALLY INSULATED CONDUCTORS TWISTED OR MOLDED TOGETHER WITHOUT A COMMON COVERING, OR ONE INSULATED CONDUCTOR WITH A METALLIC COVERING OR SHIELD; EACH HAVING CHARACTERISTICS NOT COMPLETELY CONFORMING TO CABLE, TELEPHONE; CABLE, POWER, ELECTRICAL; CABLE, RADIO FREQUENCY OR CORD, ELECTRICAL. INCLUDES ITEMS HAVING THE COMBINED CHARACTERISTICS OF TWO OR MORE OF THE AFOREMENTIONED NAMES. REFERS TO BULK QUANTITIES ONLY; FOR ITEMS OF DEFINITE LENGTH WITH PROCESSED ENDS OR TERMINATED IN FITTINGS, SEE CABLE ASSEMBLY, SPECIAL PURPOSE, ELECTRICAL.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
MPD1507 | 18876 | A | 5 | 1 | X | XX | ||
E24U9-92U | 18876 | A | 3 | 2 | X | XX | ||
MPD1507TYPEE24U9-92U | 18876 | A | 3 | 2 | 3 | BD | ||
TEH2XAWG24/19/E-CU.VS-9+92 | C1934 | A | 5 | 2 | 3 | ZG |
CAGE Information
Code | Company |
---|---|
18876 | U S ARMY AVIATION AND MISSILE COMMAN |
C1934 | HEW-KABEL/CDT GMBH & CO. KG |
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AAGR | CROSS-SECTIONAL SHAPE STYLE | TWIST |
AMQN | CONDUCTOR QUANTITY | 2 |
SFTT | SURFACE TREATMENT | SILVER CORE CONDUCTOR ALL CONDUCTORS |
ABJH | TEMP RATING | 200.0 DEG CELSIUS |
CXDQ | CONDUCTOR ARRANGEMENT AND QUANTITY | 1 TWISTED TOGETHER W/NO OUTER COVERING |
CXDC | ROUND CONDUCTOR SIZE | 24 AWG ALL CONDUCTORS |
ASGF | TRACER COLOR | RED FIRST TRACER SECOND CONDUCTOR |
CXFK | VOLTAGE RATING | 600.0 AC MAXIMUM RATED WORKING VOLTAGE ALL CONDUCTORS |
MATT | MATERIAL | COPPER CORE CONDUCTOR ALL CONDUCTORS |
MATT | MATERIAL | PLASTIC POLYTETRAFLUOROETHYLENE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS |
CXCW | CONDUCTOR FORM | STRANDED ALL CONDUCTORS |
CXDG | STRAND AWG SIZE PER CONDUCTOR | 36 ALL CONDUCTORS |
BLNZ | STRAND QUANTITY PER CONDUCTOR | 19 ALL CONDUCTORS |