National Stock Number (NSN) Output Data
Definition:
TWO OR MORE INSULATED CONDUCTORS (SOLID OR STRANDED) CONTAINED IN A COMMON COVERING, OR TWO OR MORE INSULATED CONDUCTORS TWISTED OR MOLDED TOGETHER WITHOUT A COMMON COVERING, OR ONE INSULATED CONDUCTOR WITH A METALLIC COVERING, COVERING, SHIELD, OR OUTER CONDUCTOR. THE RATED WORKING VOLTAGE OF THE ITEM MUST BE 300 VOLTS OR MORE, OR IN LIEU OF THIS THE TEST VOLTAGE MUST BE 1,000 VOLTS OR MORE; AND THE SIZE OF EACH INDIVIDUAL CONDUCTOR MUST BE NUMBER 18 AMERICAN WIRE GAGE (0.75 SQUARE MILLIMETERS) OR LARGER. FOR CABLES WITH UNINSULATED NEUTRAL CONDUCTOR USE THE HIGHTEST RATED VOLTAGE. REFERS TO BULK QUANTITIES ONLY, FOR ITEMS OF DEFINITE LENGTH WITH PROCESSED ENDS OR TERMINATED IN FITTINGS, SEE CABLE ASSEMBLY, POWER, ELECTRICAL. FOR LOW VOLTAGE AIRCRAFT AND AUTOMOTIVE CABLE, SEE CABLE, SPECIAL PURPOSE, ELECTRICAL.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
D-1701 | 04946 | A | 3 | 2 | 6 | KZ | ||
6010664-001 | 12436 | A | 5 | 9 | 2 | SB |
CAGE Information
Code | Company |
---|---|
04946 | STANDARD WIRE & CABLE CO DBA AMERICA |
12436 | BAE SYSTEMS NATIONAL SECURITY SOLUTI |
Federal Supply Class
Title
WIRE AND CABLE, ELECTRICAL
Inclusions:
INCLUDES INSULATED AND NONINSULATED, WIRE AND CABLE, SUCH AS, ANTENNA WIRE, COAXIAL CABLE, FUSE AND RESISTANCE WIRE, AND MAGNET WIRE.
Exclusions:
EXCLUDES RADIO FREQUENCY TRANSMISSION LINE (FSC 5985); FIBER OPTIC CABLE (FSC 6015); COMMUNICATION CABLE ASSEMBLIES (FSC 5995); DISTRIBUTION AND POWER TRANSMISSION CABLE ASSEMBLIES (FSC 6150).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AMQN | CONDUCTOR QUANTITY | 2 |
AAGR | CROSS-SECTIONAL SHAPE STYLE | ROUND |
HUES | COLOR | WHITE 2ND POSITION COVER SECOND CONDUCTOR |
MATT | MATERIAL | COPPER 1ST POSITION SHIELD BRAID, METALLIC CABLE |
SFTT | SURFACE TREATMENT | SILVER CORE CONDUCTOR ALL CONDUCTORS |
PRMT | PRECIOUS MATERIAL | SILVER |
HUES | COLOR | BLACK 1ST POSITION COVER FIRST CONDUCTOR |
CXDC | ROUND CONDUCTOR SIZE | 12 AWG ALL CONDUCTORS |
CXFK | VOLTAGE RATING | 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | QQ-W-343,SOFT FED SPEC SINGLE MATERIAL RESPONSE CORE CONDUCTOR ALL CONDUCTORS |
PMLC | PRECIOUS MATERIAL AND LOCATION | SURFACE ALL CONDUCTORS SILVER AND SURFACE SHIELD BRAID SILVER |
CXDQ | CONDUCTOR ARRANGEMENT AND QUANTITY | 1 TWISTED PAIR |
MATT | MATERIAL | COPPER CORE CONDUCTOR ALL CONDUCTORS |
MATT | MATERIAL | SILVER 2ND POSITION SHIELD BRAID, METALLIC CABLE |
MATT | MATERIAL | PLASTIC POLYTETRAFLUOROETHYLENE 2ND POSITION JACKET CABLE |
MATT | MATERIAL | PLASTIC POLYTETRAFLUOROETHYLENE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS |
CXCW | CONDUCTOR FORM | STRANDED ALL CONDUCTORS |
BLNZ | STRAND QUANTITY PER CONDUCTOR | 19 ALL CONDUCTORS |
CXDG | STRAND AWG SIZE PER CONDUCTOR | 25 ALL CONDUCTORS |