National Stock Number (NSN) Output Data
Definition:
TWO OR MORE INSULATED CONDUCTORS (SOLID OR STRANDED) CONTAINED IN A COMMON COVERING, OR TWO OR MORE INSULATED CONDUCTORS TWISTED OR MOLDED TOGETHER WITHOUT A COMMON COVERING, OR ONE INSULATED CONDUCTOR WITH A METALLIC COVERING, COVERING, SHIELD, OR OUTER CONDUCTOR. THE RATED WORKING VOLTAGE OF THE ITEM MUST BE 300 VOLTS OR MORE, OR IN LIEU OF THIS THE TEST VOLTAGE MUST BE 1,000 VOLTS OR MORE; AND THE SIZE OF EACH INDIVIDUAL CONDUCTOR MUST BE NUMBER 18 AMERICAN WIRE GAGE (0.75 SQUARE MILLIMETERS) OR LARGER. FOR CABLES WITH UNINSULATED NEUTRAL CONDUCTOR USE THE HIGHTEST RATED VOLTAGE. REFERS TO BULK QUANTITIES ONLY, FOR ITEMS OF DEFINITE LENGTH WITH PROCESSED ENDS OR TERMINATED IN FITTINGS, SEE CABLE ASSEMBLY, POWER, ELECTRICAL. FOR LOW VOLTAGE AIRCRAFT AND AUTOMOTIVE CABLE, SEE CABLE, SPECIAL PURPOSE, ELECTRICAL.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
E16C9-0U | 81349 | M | 2 | 2 | 4 | ZZ | ||
HMS 2-1480/2-16BU1 | 82577 | A | 5 | 1 | 4 | ZZ | ||
HMS2-1480/2-16B-U-90 | 00816 | A | C | 1 | 6 | ZZ | AC | |
E16C0-9U | 81349 | M | 5 | 1 | 4 | ZZ | ||
S10-4188 | 04569 | A | 5 | 1 | 5 | KZ | ||
EC16U9-0U | 81349 | M | 5 | 9 | 4 | ZZ | ||
5265830-007 | 53711 | A | 5 | 1 | 4 | ZZ | ||
MIL-DTL-55021/2 | 81349 | M | 4 | 1 | E | ZZ | ||
EXE16-19/29-TP-0/9 | 29005 | A | 5 | 1 | E | KZ | ||
MIL-C-55021/2 | 81349 | M | 5 | 9 | 4 | KZ |
CAGE Information
Code | Company |
---|---|
00816 | PALOMAR PRODUCTS INC. |
81349 | MILITARY SPECIFICATIONS PROMULGATED |
82577 | RAYTHEON COMPANY DBA RAYTHEON |
04569 | NATIONAL WIRE AND CABLE CORPORATION |
53711 | NAVAL SEA SYSTEMS COMMAND |
29005 | STORM PRODUCTS CO |
Federal Supply Class
Title
WIRE AND CABLE, ELECTRICAL
Inclusions:
INCLUDES INSULATED AND NONINSULATED, WIRE AND CABLE, SUCH AS, ANTENNA WIRE, COAXIAL CABLE, FUSE AND RESISTANCE WIRE, AND MAGNET WIRE.
Exclusions:
EXCLUDES RADIO FREQUENCY TRANSMISSION LINE (FSC 5985); FIBER OPTIC CABLE (FSC 6015); COMMUNICATION CABLE ASSEMBLIES (FSC 5995); DISTRIBUTION AND POWER TRANSMISSION CABLE ASSEMBLIES (FSC 6150).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AAGR | CROSS-SECTIONAL SHAPE STYLE | TWIST |
AMQN | CONDUCTOR QUANTITY | 2 |
SFTT | SURFACE TREATMENT | SILVER CORE CONDUCTOR ALL CONDUCTORS |
PRMT | PRECIOUS MATERIAL | SILVER |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | ASTM B298 ASSN STD SINGLE MATERIAL RESPONSE CORE CONDUCTOR SINGLE CONDUCTOR |
HUES | COLOR | BLACK 1ST POSITION PRIMARY INSULATION SECOND CONDUCTOR |
CXFK | VOLTAGE RATING | 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS |
CXDQ | CONDUCTOR ARRANGEMENT AND QUANTITY | 2 TWISTED TOGETHER W/NO OUTER COVERING |
HUES | COLOR | WHITE 1ST POSITION PRIMARY INSULATION FIRST CONDUCTOR |
CXDC | ROUND CONDUCTOR SIZE | 16 AWG ALL CONDUCTORS |
MATT | MATERIAL | COPPER CORE CONDUCTOR SINGLE CONDUCTOR |
PMLC | PRECIOUS MATERIAL AND LOCATION | SURFACE ALL CONDUCTORS SILVER |
MATT | MATERIAL | PLASTIC POLYTETRAFLUOROETHYLENE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS |
STDC | SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | ASTM B298 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR ALL CONDUCTORS |
CXCW | CONDUCTOR FORM | STRANDED ALL CONDUCTORS |
ADWH | CROSS-SECTIONAL WIDTH | 0.160 INCHES NOMINAL |
ABJH | TEMP RATING | -65.0 DEG CELSIUS AND 200.0 DEG CELSIUS |
FEAT | SPECIAL FEATURES | PRIMARY INSULATION CONFORMS TO L-P-403 TYPE 3 |
CXDG | STRAND AWG SIZE PER CONDUCTOR | 29 ALL CONDUCTORS |
BLNZ | STRAND QUANTITY PER CONDUCTOR | 19 ALL CONDUCTORS |
ADVN | CROSS-SECTIONAL HEIGHT | 0.080 INCHES NOMINAL |