National Stock Number (NSN) Output Data
Definition:
TWO OR MORE INSULATED CONDUCTORS (SOLID OR STRANDED) CONTAINED IN A COMMON COVERING, OR TWO OR MORE INSULATED CONDUCTORS TWISTED OR MOLDED TOGETHER WITHOUT A COMMON COVERING, OR ONE INSULATED CONDUCTOR WITH A METALLIC COVERING, COVERING, SHIELD, OR OUTER CONDUCTOR. THE RATED WORKING VOLTAGE OF THE ITEM MUST BE 300 VOLTS OR MORE, OR IN LIEU OF THIS THE TEST VOLTAGE MUST BE 1,000 VOLTS OR MORE; AND THE SIZE OF EACH INDIVIDUAL CONDUCTOR MUST BE NUMBER 18 AMERICAN WIRE GAGE (0.75 SQUARE MILLIMETERS) OR LARGER. FOR CABLES WITH UNINSULATED NEUTRAL CONDUCTOR USE THE HIGHTEST RATED VOLTAGE. REFERS TO BULK QUANTITIES ONLY, FOR ITEMS OF DEFINITE LENGTH WITH PROCESSED ENDS OR TERMINATED IN FITTINGS, SEE CABLE ASSEMBLY, POWER, ELECTRICAL. FOR LOW VOLTAGE AIRCRAFT AND AUTOMOTIVE CABLE, SEE CABLE, SPECIAL PURPOSE, ELECTRICAL.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
R3701P1619R | 23991 | A | 5 | 9 | 5 | KZ | ||
MIL-C-27500 | 81349 | M | 4 | 1 | E | KZ | ||
44A1111-16-90-9 | 06090 | A | 3 | 9 | E | KZ | ||
44AM1111-16-90-9 | 06090 | A | 5 | 9 | E | KZ |
CAGE Information
Code | Company |
---|---|
06090 | TYCO ELECTRONICS CORPORATION DIV RAY |
23991 | LOCKHEED MARTIN CORPORATION DIV LOCK |
81349 | MILITARY SPECIFICATIONS PROMULGATED |
Federal Supply Class
Title
WIRE AND CABLE, ELECTRICAL
Inclusions:
INCLUDES INSULATED AND NONINSULATED, WIRE AND CABLE, SUCH AS, ANTENNA WIRE, COAXIAL CABLE, FUSE AND RESISTANCE WIRE, AND MAGNET WIRE.
Exclusions:
EXCLUDES RADIO FREQUENCY TRANSMISSION LINE (FSC 5985); FIBER OPTIC CABLE (FSC 6015); COMMUNICATION CABLE ASSEMBLIES (FSC 5995); DISTRIBUTION AND POWER TRANSMISSION CABLE ASSEMBLIES (FSC 6150).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
HUES | COLOR | WHITE 1ST POSITION COVER SINGLE CONDUCTOR |
AAGR | CROSS-SECTIONAL SHAPE STYLE | ROUND |
ZZZW | DEPARTURE FROM CITED DOCUMENT | AS MODIFIED BY FIRST TRACER COLOR PER CONDUCTOR |
CXDQ | CONDUCTOR ARRANGEMENT AND QUANTITY | 1 SINGLES |
BLNZ | STRAND QUANTITY PER CONDUCTOR | 19 SINGLE CONDUCTOR |
SFTT | SURFACE TREATMENT | TIN CORE CONDUCTOR SINGLE CONDUCTOR |
MATT | MATERIAL | COPPER ALLOY 101 CORE CONDUCTOR SINGLE CONDUCTOR OR COPPER ALLOY 102 CORE CONDUCTOR SINGLE CONDUCTOR |
CXFK | VOLTAGE RATING | 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE SINGLE CONDUCTOR |
ASGF | TRACER COLOR | BLACK FIRST TRACER SINGLE CONDUCTOR |
CXDC | ROUND CONDUCTOR SIZE | 16 AWG SINGLE CONDUCTOR |
ADVL | CROSS SECTION OUTSIDE DIAMETER | 0.110 INCHES NOMINAL |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | ASTM B33 ASSN STD SINGLE MATERIAL RESPONSE CORE CONDUCTOR SINGLE CONDUCTOR |
HUES | COLOR | WHITE 1ST POSITION JACKET CABLE |
CXCW | CONDUCTOR FORM | STRANDED SINGLE CONDUCTOR |
STDC | SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | ASTM B33-63 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR SINGLE CONDUCTOR |
AMQN | CONDUCTOR QUANTITY | 1 |
ABJH | TEMP RATING | 150.0 DEG CELSIUS |
CXDG | STRAND AWG SIZE PER CONDUCTOR | 29 SINGLE CONDUCTOR |