National Stock Number (NSN) Output Data
Definition:
TWO OR MORE INSULATED CONDUCTORS (SOLID OR STRANDED) CONTAINED IN A COMMON COVERING, OR TWO OR MORE INSULATED CONDUCTORS TWISTED OR MOLDED TOGETHER WITHOUT A COMMON COVERING, OR ONE INSULATED CONDUCTOR WITH A METALLIC COVERING, COVERING, SHIELD, OR OUTER CONDUCTOR. THE RATED WORKING VOLTAGE OF THE ITEM MUST BE 300 VOLTS OR MORE, OR IN LIEU OF THIS THE TEST VOLTAGE MUST BE 1,000 VOLTS OR MORE; AND THE SIZE OF EACH INDIVIDUAL CONDUCTOR MUST BE NUMBER 18 AMERICAN WIRE GAGE (0.75 SQUARE MILLIMETERS) OR LARGER. FOR CABLES WITH UNINSULATED NEUTRAL CONDUCTOR USE THE HIGHTEST RATED VOLTAGE. REFERS TO BULK QUANTITIES ONLY, FOR ITEMS OF DEFINITE LENGTH WITH PROCESSED ENDS OR TERMINATED IN FITTINGS, SEE CABLE ASSEMBLY, POWER, ELECTRICAL. FOR LOW VOLTAGE AIRCRAFT AND AUTOMOTIVE CABLE, SEE CABLE, SPECIAL PURPOSE, ELECTRICAL.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
20709-01000R | 07909 | A | 3 | 2 | 3 | ZZ | ||
A36904 | 07909 | A | 5 | 9 | 4 | ZZ |
CAGE Information
Code | Company |
---|---|
07909 | SOUTHWIRE COMPANY DOUGLAS PLANT |
Federal Supply Class
Title
WIRE AND CABLE, ELECTRICAL
Inclusions:
INCLUDES INSULATED AND NONINSULATED, WIRE AND CABLE, SUCH AS, ANTENNA WIRE, COAXIAL CABLE, FUSE AND RESISTANCE WIRE, AND MAGNET WIRE.
Exclusions:
EXCLUDES RADIO FREQUENCY TRANSMISSION LINE (FSC 5985); FIBER OPTIC CABLE (FSC 6015); COMMUNICATION CABLE ASSEMBLIES (FSC 5995); DISTRIBUTION AND POWER TRANSMISSION CABLE ASSEMBLIES (FSC 6150).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AAGR | CROSS-SECTIONAL SHAPE STYLE | ROUND |
ADZC | ENVIRONMENTAL PROTECTION | WATERPROOF AND OIL RESISTANT AND WEATHERPROOF |
HUES | COLOR | BLACK 1ST POSITION PRIMARY INSULATION FIRST CONDUCTOR |
CXDQ | CONDUCTOR ARRANGEMENT AND QUANTITY | 4 SINGLES |
HUES | COLOR | RED 1ST POSITION PRIMARY INSULATION THIRD CONDUCTOR |
CXFK | VOLTAGE RATING | 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS |
MATT | MATERIAL | COPPER CORE CONDUCTOR ALL CONDUCTORS |
CXDC | ROUND CONDUCTOR SIZE | 16 AWG ALL CONDUCTORS |
FEAT | SPECIAL FEATURES | MATERIAL-EPR INSULATION, CPE JACKET |
CXDG | STRAND AWG SIZE PER CONDUCTOR | 30 ALL CONDUCTORS |
HUES | COLOR | GREEN 1ST POSITION PRIMARY INSULATION FOURTH CONDUCTOR |
ADVL | CROSS SECTION OUTSIDE DIAMETER | 0.410 INCHES NOMINAL |
CXCW | CONDUCTOR FORM | STRANDED ALL CONDUCTORS |
HUES | COLOR | WHITE 1ST POSITION PRIMARY INSULATION SECOND CONDUCTOR |
AMQN | CONDUCTOR QUANTITY | 4 |
BLNZ | STRAND QUANTITY PER CONDUCTOR | 19 ALL CONDUCTORS |
HUES | COLOR | BLACK 2ND POSITION JACKET CORD |
AGAV | END ITEM IDENTIFICATION | NSN 4120-01-449-0459; AIR CONDITIONER |
ABJH | TEMP RATING | 105.0 DEG CELSIUS |