Part Number
Definition:
TWO OR MORE INSULATED CONDUCTORS (SOLID OR STRANDED) CONTAINED IN A COMMON COVERING, OR TWO OR MORE INSULATED CONDUCTORS TWISTED OR MOLDED TOGETHER WITHOUT A COMMON COVERING, OR ONE INSULATED CONDUCTOR WITH A METALLIC COVERING, COVERING, SHIELD, OR OUTER CONDUCTOR. THE RATED WORKING VOLTAGE OF THE ITEM MUST BE 300 VOLTS OR MORE, OR IN LIEU OF THIS THE TEST VOLTAGE MUST BE 1,000 VOLTS OR MORE; AND THE SIZE OF EACH INDIVIDUAL CONDUCTOR MUST BE NUMBER 18 AMERICAN WIRE GAGE (0.75 SQUARE MILLIMETERS) OR LARGER. FOR CABLES WITH UNINSULATED NEUTRAL CONDUCTOR USE THE HIGHTEST RATED VOLTAGE. REFERS TO BULK QUANTITIES ONLY, FOR ITEMS OF DEFINITE LENGTH WITH PROCESSED ENDS OR TERMINATED IN FITTINGS, SEE CABLE ASSEMBLY, POWER, ELECTRICAL. FOR LOW VOLTAGE AIRCRAFT AND AUTOMOTIVE CABLE, SEE CABLE, SPECIAL PURPOSE, ELECTRICAL.
CAGE Information
Code | Company |
---|---|
SCY13 | E.C.A ETABLISSEMENT CENTRAL DES APPR |
Federal Supply Class
Title
WIRE AND CABLE, ELECTRICAL
Inclusions:
INCLUDES INSULATED AND NONINSULATED, WIRE AND CABLE, SUCH AS, ANTENNA WIRE, COAXIAL CABLE, FUSE AND RESISTANCE WIRE, AND MAGNET WIRE.
Exclusions:
EXCLUDES RADIO FREQUENCY TRANSMISSION LINE (FSC 5985); FIBER OPTIC CABLE (FSC 6015); COMMUNICATION CABLE ASSEMBLIES (FSC 5995); DISTRIBUTION AND POWER TRANSMISSION CABLE ASSEMBLIES (FSC 6150).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AAGR | CROSS-SECTIONAL SHAPE STYLE | ROUND |
AAGR | CROSS-SECTIONAL SHAPE STYLE | ROUND |
ADVL | CROSS SECTION OUTSIDE DIAMETER | 0.340 INCHES NOMINAL |
SFTT | SURFACE TREATMENT | TIN CORE CONDUCTOR SINGLE CONDUCTOR |
CXFK | VOLTAGE RATING | 600.0 AC MAXIMUM RATED WORKING VOLTAGE ALL CONDUCTORS |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | QQ-W-343,SOFT FED SPEC SINGLE MATERIAL RESPONSE CORE CONDUCTOR ALL CONDUCTORS |
MATT | MATERIAL | COPPER CORE CONDUCTOR ALL CONDUCTORS |
MATT | MATERIAL | RUBBER BUTADIENE-STYRENE CLASS SBR 1ST POSITION JACKET CABLE AND RUBBER CHLOROPRENE CLASS CR 1ST POSITION JACKET CABLE |
BLNZ | STRAND QUANTITY PER CONDUCTOR | 41 ALL CONDUCTORS |
AMQN | CONDUCTOR QUANTITY | 3 |
CXCW | CONDUCTOR FORM | STRANDED ALL CONDUCTORS |
STDC | SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | ASTM B33-63 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR SINGLE CONDUCTOR |
CXDC | ROUND CONDUCTOR SIZE | 18 AWG ALL CONDUCTORS |
ABJH | TEMP RATING | -40.0 DEG CELSIUS AND 75.0 DEG CELSIUS |
CXDQ | CONDUCTOR ARRANGEMENT AND QUANTITY | 3 SINGLES |
CXDG | STRAND AWG SIZE PER CONDUCTOR | 34 ALL CONDUCTORS |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | MIL-I-3930,TYPE JS OR JN MIL SPEC SINGLE MATERIAL RESPONSE 1ST POSITION JACKET CABLE |