National Stock Number (NSN) Output Data
Definition:
TWO OR MORE INSULATED CONDUCTORS (SOLID OR STRANDED) CONTAINED IN A COMMON COVERING, OR TWO OR MORE INSULATED CONDUCTORS TWISTED OR MOLDED TOGETHER WITHOUT A COMMON COVERING, OR ONE INSULATED CONDUCTOR WITH A METALLIC COVERING, COVERING, SHIELD, OR OUTER CONDUCTOR. THE RATED WORKING VOLTAGE OF THE ITEM MUST BE 300 VOLTS OR MORE, OR IN LIEU OF THIS THE TEST VOLTAGE MUST BE 1,000 VOLTS OR MORE; AND THE SIZE OF EACH INDIVIDUAL CONDUCTOR MUST BE NUMBER 18 AMERICAN WIRE GAGE (0.75 SQUARE MILLIMETERS) OR LARGER. FOR CABLES WITH UNINSULATED NEUTRAL CONDUCTOR USE THE HIGHTEST RATED VOLTAGE. REFERS TO BULK QUANTITIES ONLY, FOR ITEMS OF DEFINITE LENGTH WITH PROCESSED ENDS OR TERMINATED IN FITTINGS, SEE CABLE ASSEMBLY, POWER, ELECTRICAL. FOR LOW VOLTAGE AIRCRAFT AND AUTOMOTIVE CABLE, SEE CABLE, SPECIAL PURPOSE, ELECTRICAL.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
MIL-C-27500 | 81349 | M | 4 | 1 | E | KZ | ||
M27500-18NK2T12 | 81349 | M | 2 | 2 | E | KZ |
CAGE Information
Code | Company |
---|---|
81349 | MILITARY SPECIFICATIONS PROMULGATED |
Federal Supply Class
Title
WIRE AND CABLE, ELECTRICAL
Inclusions:
INCLUDES INSULATED AND NONINSULATED, WIRE AND CABLE, SUCH AS, ANTENNA WIRE, COAXIAL CABLE, FUSE AND RESISTANCE WIRE, AND MAGNET WIRE.
Exclusions:
EXCLUDES RADIO FREQUENCY TRANSMISSION LINE (FSC 5985); FIBER OPTIC CABLE (FSC 6015); COMMUNICATION CABLE ASSEMBLIES (FSC 5995); DISTRIBUTION AND POWER TRANSMISSION CABLE ASSEMBLIES (FSC 6150).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
STDC | SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | ASTM B33 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR ALL CONDUCTORS |
AMQN | CONDUCTOR QUANTITY | 2 |
AAGR | CROSS-SECTIONAL SHAPE STYLE | ROUND |
SFTT | SURFACE TREATMENT | TIN 4TH POSITION SHIELD BRAID, METALLIC CABLE |
MATT | MATERIAL | PLASTIC POLYIMIDE 5TH POSITION TAPE CABLE AND PLASTIC POLYIMIDE 1ST POSITION TAPE ALL CONDUCTORS AND PLASTIC POLYIMIDE 2ND POSITION TAPE ALL CONDUCTORS AND PLASTIC FLUORINATED ETHYLENE PROPYLENE 1ST POSITION TAPE ALL CONDUCTORS AND PLASTIC FLUORINATED ETHYLENE PROPYLENE 5TH POSITION TAPE CABLE AND PLASTIC FLUORINATED ETHYLENE PROPYLENE 2ND POSITION TAPE ALL CONDUCTORS AND COPPER 4TH POSITION SHIELD BRAID, METALLIC CABLE |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | ASTM B33 ASSN STD SINGLE MATERIAL RESPONSE CORE CONDUCTOR ALL CONDUCTORS |
MATT | MATERIAL | PLASTIC POLYIMIDE 3RD POSITION COATING ALL CONDUCTORS |
MATT | MATERIAL | PLASTIC POLYIMIDE 5TH POSITION TAPE CABLE |
CXFK | VOLTAGE RATING | 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS |
MATT | MATERIAL | PLASTIC FLUORINATED ETHYLENE PROPYLENE 1ST POSITION TAPE ALL CONDUCTORS |
CXDQ | CONDUCTOR ARRANGEMENT AND QUANTITY | 2 SINGLES |
MATT | MATERIAL | COPPER CORE CONDUCTOR ALL CONDUCTORS |
MATT | MATERIAL | PLASTIC FLUORINATED ETHYLENE PROPYLENE 2ND POSITION TAPE ALL CONDUCTORS |
CXDG | STRAND AWG SIZE PER CONDUCTOR | 30 ALL CONDUCTORS |
SFTT | SURFACE TREATMENT | TIN CORE CONDUCTOR ALL CONDUCTORS |
CXCW | CONDUCTOR FORM | STRANDED ALL CONDUCTORS |
CXDC | ROUND CONDUCTOR SIZE | 18 AWG ALL CONDUCTORS |
BLNZ | STRAND QUANTITY PER CONDUCTOR | 19 ALL CONDUCTORS |
HUES | COLOR | WHITE 1ST POSITION TAPE ALL CONDUCTORS |
ABJH | TEMP RATING | 150.0 DEG CELSIUS |
ASGF | TRACER COLOR | BLUE SINGLE TRACER SECOND CONDUCTOR |