National Stock Number (NSN) Output Data
Definition:
TWO OR MORE INSULATED CONDUCTORS (SOLID OR STRANDED) CONTAINED IN A COMMON COVERING, OR TWO OR MORE INSULATED CONDUCTORS TWISTED OR MOLDED TOGETHER WITHOUT A COMMON COVERING, OR ONE INSULATED CONDUCTOR WITH A METALLIC COVERING, COVERING, SHIELD, OR OUTER CONDUCTOR. THE RATED WORKING VOLTAGE OF THE ITEM MUST BE 300 VOLTS OR MORE, OR IN LIEU OF THIS THE TEST VOLTAGE MUST BE 1,000 VOLTS OR MORE; AND THE SIZE OF EACH INDIVIDUAL CONDUCTOR MUST BE NUMBER 18 AMERICAN WIRE GAGE (0.75 SQUARE MILLIMETERS) OR LARGER. FOR CABLES WITH UNINSULATED NEUTRAL CONDUCTOR USE THE HIGHTEST RATED VOLTAGE. REFERS TO BULK QUANTITIES ONLY, FOR ITEMS OF DEFINITE LENGTH WITH PROCESSED ENDS OR TERMINATED IN FITTINGS, SEE CABLE ASSEMBLY, POWER, ELECTRICAL. FOR LOW VOLTAGE AIRCRAFT AND AUTOMOTIVE CABLE, SEE CABLE, SPECIAL PURPOSE, ELECTRICAL.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
1576AS954-1 | 30003 | A | 3 | 2 | 5 | ZZ | ||
5078 | 92194 | Y | 3 | 2 | 4 | ZZ |
CAGE Information
Code | Company |
---|---|
30003 | NAVAL AIR SYSTEMS COMMAND |
92194 | ALPHA WIRE CORP |
Federal Supply Class
Title
WIRE AND CABLE, ELECTRICAL
Inclusions:
INCLUDES INSULATED AND NONINSULATED, WIRE AND CABLE, SUCH AS, ANTENNA WIRE, COAXIAL CABLE, FUSE AND RESISTANCE WIRE, AND MAGNET WIRE.
Exclusions:
EXCLUDES RADIO FREQUENCY TRANSMISSION LINE (FSC 5985); FIBER OPTIC CABLE (FSC 6015); COMMUNICATION CABLE ASSEMBLIES (FSC 5995); DISTRIBUTION AND POWER TRANSMISSION CABLE ASSEMBLIES (FSC 6150).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AAGR | CROSS-SECTIONAL SHAPE STYLE | ROUND |
BLNZ | STRAND QUANTITY PER CONDUCTOR | 26 ALL CONDUCTORS |
HUES | COLOR | BLACK 1ST POSITION PRIMARY INSULATION FIRST CONDUCTOR |
HUES | COLOR | WHITE 1ST POSITION PRIMARY INSULATION THIRD CONDUCTOR |
CXDQ | CONDUCTOR ARRANGEMENT AND QUANTITY | 8 SINGLES |
MATT | MATERIAL | COPPER CORE CONDUCTOR ALL CONDUCTORS |
CXDC | ROUND CONDUCTOR SIZE | 16 AWG ALL CONDUCTORS |
CXDG | STRAND AWG SIZE PER CONDUCTOR | 30 ALL CONDUCTORS |
HUES | COLOR | BROWN 1ST POSITION PRIMARY INSULATION SINGLE CONDUCTOR |
HUES | COLOR | GREEN 1ST POSITION PRIMARY INSULATION FOURTH CONDUCTOR |
ADVL | CROSS SECTION OUTSIDE DIAMETER | 0.410 INCHES NOMINAL |
AMQN | CONDUCTOR QUANTITY | 8 |
HUES | COLOR | BLUE 1ST POSITION PRIMARY INSULATION SIXTH CONDUCTOR |
CXCW | CONDUCTOR FORM | STRANDED ALL CONDUCTORS |
CXFK | VOLTAGE RATING | 300.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS |
HUES | COLOR | ORANGE 1ST POSITION PRIMARY INSULATION FIFTH CONDUCTOR |
MATT | MATERIAL | PLASTIC POLYVINYL CHLORIDE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS |
SFTT | SURFACE TREATMENT | TIN ALLOY CORE CONDUCTOR ALL CONDUCTORS |
HUES | COLOR | YELLOW 1ST POSITION PRIMARY INSULATION EIGHTH CONDUCTOR |
MATT | MATERIAL | PLASTIC POLYVINYL CHLORIDE 3RD POSITION JACKET CABLE |
ABJH | TEMP RATING | -20.0 DEG CELSIUS AND 80.0 DEG CELSIUS |
HUES | COLOR | RED 1ST POSITION PRIMARY INSULATION SECOND CONDUCTOR |
MATT | MATERIAL | PLASTIC NYLON 2ND POSITION WRAP CABLE |