National Stock Number (NSN) Output Data
Definition:
TWO OR MORE INSULATED CONDUCTORS (SOLID OR STRANDED) CONTAINED IN A COMMON COVERING, OR TWO OR MORE INSULATED CONDUCTORS TWISTED OR MOLDED TOGETHER WITHOUT A COMMON COVERING, OR ONE INSULATED CONDUCTOR WITH A METALLIC COVERING, COVERING, SHIELD, OR OUTER CONDUCTOR. THE RATED WORKING VOLTAGE OF THE ITEM MUST BE 300 VOLTS OR MORE, OR IN LIEU OF THIS THE TEST VOLTAGE MUST BE 1,000 VOLTS OR MORE; AND THE SIZE OF EACH INDIVIDUAL CONDUCTOR MUST BE NUMBER 18 AMERICAN WIRE GAGE (0.75 SQUARE MILLIMETERS) OR LARGER. FOR CABLES WITH UNINSULATED NEUTRAL CONDUCTOR USE THE HIGHTEST RATED VOLTAGE. REFERS TO BULK QUANTITIES ONLY, FOR ITEMS OF DEFINITE LENGTH WITH PROCESSED ENDS OR TERMINATED IN FITTINGS, SEE CABLE ASSEMBLY, POWER, ELECTRICAL. FOR LOW VOLTAGE AIRCRAFT AND AUTOMOTIVE CABLE, SEE CABLE, SPECIAL PURPOSE, ELECTRICAL.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
1576AS907-1 | 30003 | A | 7 | 2 | A | ZZ | ||
02769 | 81774 | A | 3 | 2 | 4 | ZZ | ||
W4338 | 82879 | A | 5 | 9 | 4 | ZZ | ||
1934/3 | 92194 | Y | 3 | 1 | 4 | ZZ | ||
1934/3 | 92184 | A | C | 1 | 1 | ZZ | AC |
CAGE Information
Code | Company |
---|---|
30003 | NAVAL AIR SYSTEMS COMMAND |
81774 | GENERAL CABLE CORPORATION DBA GENERA |
82879 | YORK TECHNICAL INSTITUTE LLC DBA YTI |
92194 | ALPHA WIRE CORP |
92184 | ULSTER FOUNDRY AND MACHINE CORP |
Federal Supply Class
Title
WIRE AND CABLE, ELECTRICAL
Inclusions:
INCLUDES INSULATED AND NONINSULATED, WIRE AND CABLE, SUCH AS, ANTENNA WIRE, COAXIAL CABLE, FUSE AND RESISTANCE WIRE, AND MAGNET WIRE.
Exclusions:
EXCLUDES RADIO FREQUENCY TRANSMISSION LINE (FSC 5985); FIBER OPTIC CABLE (FSC 6015); COMMUNICATION CABLE ASSEMBLIES (FSC 5995); DISTRIBUTION AND POWER TRANSMISSION CABLE ASSEMBLIES (FSC 6150).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
STDC | SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | ASTM B33 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR ALL CONDUCTORS |
AAGR | CROSS-SECTIONAL SHAPE STYLE | ROUND |
MATT | MATERIAL | PLASTIC POLYAMIDE 2ND POSITION JACKET ALL CONDUCTORS |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | ASTM B33 ASSN STD SINGLE MATERIAL RESPONSE CORE CONDUCTOR ALL CONDUCTORS |
HUES | COLOR | BLACK 1ST POSITION PRIMARY INSULATION FIRST CONDUCTOR |
CXFK | VOLTAGE RATING | 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS |
CXDQ | CONDUCTOR ARRANGEMENT AND QUANTITY | 1 TRIPLES |
SFTT | SURFACE TREATMENT | TIN 3RD POSITION SHIELD BRAID, METALLIC CABLE |
MATT | MATERIAL | COPPER CORE CONDUCTOR ALL CONDUCTORS |
HUES | COLOR | BLACK 4TH POSITION JACKET CABLE |
CXDG | STRAND AWG SIZE PER CONDUCTOR | 30 ALL CONDUCTORS |
SFTT | SURFACE TREATMENT | TIN CORE CONDUCTOR ALL CONDUCTORS |
MATT | MATERIAL | PLASTIC POLYURETHANE 4TH POSITION JACKET CABLE |
AMQN | CONDUCTOR QUANTITY | 3 |
CXCW | CONDUCTOR FORM | STRANDED ALL CONDUCTORS |
MATT | MATERIAL | PLASTIC POLYVINYL CHLORIDE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS |
CXDC | ROUND CONDUCTOR SIZE | 18 AWG ALL CONDUCTORS |
HUES | COLOR | WHITE 1ST POSITION PRIMARY INSULATION SECOND CONDUCTOR |
MATT | MATERIAL | COPPER 3RD POSITION SHIELD BRAID, METALLIC CABLE |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | MIL-I-3930/21 MIL SPEC SINGLE MATERIAL RESPONSE 4TH POSITION JACKET CABLE |
ADVL | CROSS SECTION OUTSIDE DIAMETER | 0.290 INCHES NOMINAL |
BLNZ | STRAND QUANTITY PER CONDUCTOR | 19 ALL CONDUCTORS |
HUES | COLOR | GREEN 1ST POSITION PRIMARY INSULATION THIRD CONDUCTOR |
ABJH | TEMP RATING | -40.0 DEG CELSIUS AND 80.0 DEG CELSIUS |