NIIN:
Item Name:
HEATER , SPACE

Definition:

A DEVICE DESIGNED TO BURN VARIOUS TYPES OF FUEL WITHIN AN INCLOSURE WHICH PROTECTS AND CONFINES THE FIRE. IT IS USED FOR THE PURPOSE OF RAISING THE TEMPERATURE OF THE AIR IN ITS IMMEDIATE VICINITY. THE INCLOSURE MAY BE VENTED. EXCLUDES HEATER, DUCT TYPE, PORTABLE AND HEATER, SPACE, ELECTRIC.

CAGE Information

Code Company
0JKN0 HDT EXPEDITIONARY SYSTEMS INC.

Federal Supply Class

Title

SPACE AND WATER HEATING EQUIPMEN

Inclusions:

INCLUDES BOILERS, 15 POUNDS WSP AND UNDER (FOR BOILERS OVER 15 POUNDS WSP, SEE FSC 4410); DOMESTIC WATER STORAGE TANKS THROUGH 100 GALLON CAPACITY; FIREPLACE HEATERS; FURNACES; SPACE HEATERS; HEATING RADIATORS; IMMERSION HEATERS; WATER HEATERS, THROUGH 100 GALLON RECOVERY CAPACITY (FOR HEATERS OVER 100 GALLONS RECOVERY CAPACITY, SEE FSC 4410).

Exclusions:

EXCLUDES VEHICLE HEATERS; (FSC 2540); AIRCRAFT HEATERS (FSC 1660).

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
ABBA AIR CIRCULATION DEVICE PROPELLER FAN
CXCY PART NAME ASSIGNED BY CONTROLLING AGENCY HEATER PORT150
ABMZ DIAMETER 56.000 INCHES NOMINAL
ABGL WIDTH 26.000 INCHES NOMINAL
CQXD HEAT DELIVERY RATE 120000.0 BRITISH THERMAL UNIT
FUEL FUEL TYPE DIESEL FUEL OIL AND JP8
SUPP SUPPLEMENTARY FEATURES HEATER 120K BTU/H, W/2 EACH 16 INCH X 10 FT DUCTS (IN STOCK)
FEAT SPECIAL FEATURES AIR FLOW 1100 CFM AT 1.5 IWG; FUEL TANK CAPACITY 22 GALLONS; FUEL REQUIREMENTS DF1, DF2, DFA, AND JP8; FUEL USAGE 1.25 GALLONS PER HOUR; POWER REQUIREMENTS 120VAC-60HZ; POWER USAGE 12 AMPS
HGTH HEIGHT 31.000 INCHES NOMINAL
AGAV END ITEM IDENTIFICATION NAVAL EXPEDITIONARY MISC EQUIPMENT

Similar Parts