Part Number
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
CAGE Information
Code | Company |
---|---|
07690 | BAE SYSTEMS CONTROLS INC |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ADAU | BODY HEIGHT | 1.550 INCHES NOMINAL |
AAJD | THREAD CLASS (NON-CORE) | 2B SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 60.00 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT 2ND WINDING |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
CRBZ | WINDING OPERATING CURRENT | 12.0 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 3RD WINDING |
AKPV | MOUNTING FACILITY QUANTITY | 2 SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 40.00 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT 3RD WINDING |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
AAJF | THREAD DIRECTION (NON-CORE) | RIGHT-HAND SINGLE GROUP |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 1.000 INCHES NOMINAL ALL MOUNTING FACILITIES ALL CENTER GROUPINGS |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
CQLC | WINDING TAP LOCATION (NON-CORE) | CENTER TAP ALL COMPONENTS ALL WINDING |
ACZB | FREQUENCY RATING | 49.0 KILOHERTZ MINIMUM ALL COMPONENTS AND 51.0 KILOHERTZ MAXIMUM ALL COMPONENTS |
ADAQ | BODY LENGTH | 1.550 INCHES NOMINAL |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL ALL COMPONENTS |
CQJX | NOMINAL THREAD SIZE | 0.112 INCHES SINGLE GROUP |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE ALL COMPONENTS |
CRBZ | WINDING OPERATING CURRENT | 680.0 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 2ND WINDING |
ADAT | BODY WIDTH | 1.400 INCHES NOMINAL |
AASA | THREAD LENGTH (NON-CORE) | 0.150 INCHES MINIMUM SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 10 WIRE LEAD |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.000 INCHES NOMINAL ALL MOUNTING FACILITIES ALL CENTER GROUPINGS |
CRBZ | WINDING OPERATING CURRENT | 27.5 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 1ST WINDING |
CWJS | WINDING OPERATING VOLTAGE | 60.00 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT 1ST WINDING |