Part Number
Part Number:
NSN:
NIIN:
Item Name:
ADAPTER , WAVEGUIDE
Definition:
AN ITEM DESIGNED TO ESTABLISH THE NECESSARY ACCOMMODATIONS TO CONNECT A WAVEGUIDE TO A COAXIAL LINE, OR TO CONNECT TWO OR MORE TERMINATED WAVEGUIDES WHOSE PHYSICAL DESIGN DOES NOT NORMALLY ALLOW CONNECTION.
CAGE Information
Code | Company |
---|---|
00929 | MICROLAB/FXR |
Federal Supply Class
Title
ANTENNAS, WAVEGUIDES, AND RELATE
Inclusions:
INCLUDES AERIALS; MASTS; TOWER EQUIPMENT; ATTENUATORS; COUPLERS; TRANSMISSION LINES.
Exclusions:
EXCLUDES TOWER STRUCTURES.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CTCJ | FLANGE STYLE | CHOKE TYPE FIRST FLANGE |
AHTD | FLANGE DEPTH | 0.500 INCHES NOMINAL SECOND FLANGE |
AHTX | INSERTION LOSS IN DECIBELS | 0.03 |
FEAT | SPECIAL FEATURES | MTG HOLES FOR 1ST FLANGE P/N M3922/60-001 ARE ALTERED; COOLING TUBE AROUND WAVEGUIDE TUBE |
BBPN | ADAPTER LENGTH | 6.500 INCHES NOMINAL |
AHSF | FLANGE QUANTITY | 2 |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS ALL TUBING SEGMENT |
CSFC | WAVEGUIDE OUTSIDE HEIGHT | 0.750 INCHES NOMINAL |
CRFH | WAVEGUIDE INSIDE WIDTH | 1.372 INCHES NOMINAL |
AHSX | FLANGE INSIDE WIDTH | 1.122 INCHES NOMINAL SECOND FLANGE |
STDC | SURFACE TREATMENT DOCUMENT AND CLASSIFICATION (NON-CORE) | SM-F-796489-80063 MFR REF ALL TREATMENT RESPONSES SINGLE TUBING SEGMENT ALL SURFACES |
AHTC | FLANGE OUTSIDE DIAMETER | 3.125 INCHES NOMINAL FIRST FLANGE |
CTCJ | FLANGE STYLE | CONTACT TYPE SECOND FLANGE |
AHSY | FLANGE INSIDE HEIGHT | 0.497 INCHES NOMINAL SECOND FLANGE |
AHTA | FLANGE OUTSIDE HEIGHT | 1.750 INCHES NOMINAL SECOND FLANGE |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.169 INCHES NOMINAL SECOND FLANGE ALL CONNECTION FACILITIES |
STYL | STYLE DESIGNATOR | WAVEGUIDE TO WAVEGUIDE |
CRLB | WAVEGUIDE INSIDE HEIGHT | 0.622 INCHES NOMINAL |
CQHN | WAVEGUIDE OUTSIDE WIDTH | 1.500 INCHES NOMINAL |
AHSX | FLANGE INSIDE WIDTH | 1.372 INCHES NOMINAL FIRST FLANGE |
AHTD | FLANGE DEPTH | 0.750 INCHES NOMINAL FIRST FLANGE |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 6 UNTHREADED HOLE FIRST FLANGE ALL CONNECTION FACILITIES |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 8 UNTHREADED HOLE SECOND FLANGE ALL CONNECTION FACILITIES |
SPCL | SPECIAL TEST FEATURES | LEAK RATE OF ASSY TO BE ZERO CFH STD AIR AT 0.5 PSIG |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.203 INCHES NOMINAL FIRST FLANGE ALL CONNECTION FACILITIES |
AAGR | CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
SFTT | SURFACE TREATMENT | PAINT ALL TUBING SEGMENT AND FLANGE ALL SURFACES |
AHSY | FLANGE INSIDE HEIGHT | 0.622 INCHES NOMINAL FIRST FLANGE |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.05 |
AHSZ | FLANGE OUTSIDE WIDTH | 2.500 INCHES NOMINAL SECOND FLANGE |
MATT | MATERIAL | ALUMINUM ALLOY SINGLE TUBING SEGMENT OR COPPER ALLOY SINGLE TUBING SEGMENT |