Part Number
Part Number:
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
CAGE Information
Code | Company |
---|---|
94696 | SE RELAYS LLC MAGNECRAFT DIV SE RELA |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES AC RESISTIVE LOAD AND 2.0 AMPERES DC RESISTIVE LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES AC RESISTIVE LOAD AND 2.0 AMPERES DC RESISTIVE LOAD |
AKDX | WINDING QUANTITY | 1 |
AAJD | THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
CQJX | NOMINAL THREAD SIZE | 0.086 INCHES SINGLE MOUNTING FACILITY |
CRXH | TIME DELAY | 0.005 SECONDS NOMINAL FIXED OPERATE AND RELEASE TIME |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 0.610 INCHES NOMINAL |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 4 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 12.0 VOLTS TEARDROP, TWO HOLES TYPE 4F SINGLE WINDING |
APCN | COIL QUANTITY | 1 |
CBBL | FEATURES PROVIDED | POLARIZED |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 100.0 MILLIAMPERES DC SINGLE WINDING |
ABMK | OVERALL WIDTH | 0.810 INCHES NOMINAL |
CMLP | THREAD QUANTITY PER INCH | 56 SINGLE MOUNTING FACILITY |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
ABHP | OVERALL LENGTH | 1.415 INCHES NOMINAL |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
AEBW | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT | 0.400 INCHES NOMINAL SINGLE MOUNTING FACILITY |
APNP | DUTY TYPE | CONTINUOUS |
TTQY | TERMINAL TYPE AND QUANTITY | 14 PIN ALL FUNCTIONS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED STUD SINGLE MOUNTING FACILITY |
APNA | WINDING DC RESISTANCE RATING | 117.0 OHMS NOMINAL SINGLE WINDING |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.200 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |