Part Number
Part Number:
NSN:
NIIN:
Item Name:
FAN , TUBEAXIAL
Definition:
A NONPOSITIVE DISPLACEMENT MECHANICAL DEVICE WITHOUT GUIDE VANES AND HAVING AN AXIAL FAN IMPELLER INCLOSED WITHIN A TUBULAR HOUSING. IT IS DESIGNED PRIMARILY FOR DUCT INSTALLATION TO MOVE AIR OR GAS AXIALLY OVER A WIDE RANGE OF VOLUMES AT MEDIUM PRESSURES.
CAGE Information
Code | Company |
---|---|
19315 | HONEYWELL INTL INC DEFENSE AVIONICS |
Federal Supply Class
Title
FANS, AIR CIRCULATORS, AND BLOWE
Inclusions:
INCLUDES WALL TYPE FANS; PEDESTAL TYPE FANS; HOUSEHOLD TYPE AND ATTIC TYPE EXHAUST FANS; FLOOR FANS; FORGED DRAFT EXHAUST AND DISPOSAL KITS; FANS, AIR CIRCULATORS, AND BLOWER EQUIPMENT, WHETHER DESIGNATED AS "INDUSTRIAL" OR "NONINDUSTRIAL" BY APPLICATION AND/OR USE.
Exclusions:
EXCLUDES COMBINATION HEATER-FANS (FSC 4520).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CQKX | AIR FLOW RATE | 133.0 CUBIC FEET PER MINUTE NOMINAL |
ABRY | LENGTH | 1.500 INCHES NOMINAL |
AYSY | ROTATION DIRECTION FOR WHICH DESIGNED | COUNTERCLOCKWISE |
HGTH | HEIGHT | 4.500 INCHES NOMINAL |
ABGL | WIDTH | 4.690 INCHES NOMINAL |
STYL | STYLE DESIGNATOR | FIXED |
AKCV | DRIVE TYPE | DIRECT |
AJLY | STATIC PRESSURE AT SPECIFIED AIR FLOW RATE | 5.0 INCHES OF WATER |
STDC | SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | MIL-C-5541,TYPE1 MIL SPEC 1ST TREATMENT RESPONSE HOUSING |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | QQ-A-591 MIL SPEC 1ST MATERIAL RESPONSE HOUSING |
MATT | MATERIAL | ALUMINUM HOUSING |
SFTT | SURFACE TREATMENT | CHROMATE HOUSING |
AEQC | OPERATING SPEED AT RATED CAPACITY IN RPM | 3800.0 |
MATT | MATERIAL | PLASTIC POLYCARBONATE BLADE |
CSBH | VOLTAGE IN VOLTS AND CURRENT TYPE | 26.0 DC |
TEST | TEST DATA DOCUMENT | 82877-011036 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL |
CWLX | HOUSING INSIDE DIAMETER | 4.125 INCHES NOMINAL |