Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC

Definition:

A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.

CAGE Information

Code Company
001JK EMBRAER S/A

Federal Supply Class

Title

RELAYS AND SOLENOIDS

Inclusions:

INCLUDES ELECTROMAGNETIC ACTUATORS.

Exclusions:

EXCLUDES CONTRACTORS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 2.0 AMPERES AC LAMP LOAD AND 2.0 AMPERES DC LAMP LOAD
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 2.0 AMPERES AC LAMP LOAD AND 2.0 AMPERES DC LAMP LOAD
AKDX WINDING QUANTITY 1
BBRG STORAGE TYPE GENERAL PURPOSE WAREHOUSE
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 2.125 INCHES NOMINAL FIRST MOUNTING FACILITY
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 1.000 INCHES NOMINAL FIRST MOUNTING FACILITY
CBME CUBIC MEASURE 10.562 CUBIC INCHES
AFJN FRAGILITY FACTOR MODERATELY RUGGED
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 2.125 INCHES NOMINAL SECOND MOUNTING FACILITY
APNA WINDING DC RESISTANCE RATING 160.0 OHMS NOMINAL SINGLE WINDING
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 1.000 INCHES NOMINAL SECOND MOUNTING FACILITY
AXHR MOUNTING FACILITY TYPE AND QUANTITY 4 UNTHREADED HOLE FIRST MOUNTING FACILITY
TEST TEST DATA DOCUMENT 81349-MIL-R-6106 SPECIFICATION
APCN COIL QUANTITY 1
CRXH TIME DELAY 0.025 SECONDS MAXIMUM FIXED OPERATE TIME
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 6.0 AMPERES AC MOTOR LOAD AND 6.0 AMPERES DC MOTOR LOAD
AXHR MOUNTING FACILITY TYPE AND QUANTITY 4 UNTHREADED HOLE SECOND MOUNTING FACILITY
ABHP OVERALL LENGTH 2.500 INCHES MAXIMUM
CWAB MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 115.0 AC AND 28.0 DC
APNQ ARC QUENCHING METHOD AIR
AKSL PURPOSE FOR WHICH DESIGNED GENERAL
CSXF OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
ADZC ENVIRONMENTAL PROTECTION HERMETIC
ABKW OVERALL HEIGHT 2.600 INCHES MAXIMUM
APNP DUTY TYPE CONTINUOUS
CQYJ MOUNTING FACILITY PATTERN RECTANGULAR FIRST MOUNTING FACILITY
ABMK OVERALL WIDTH 1.625 INCHES MAXIMUM
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 10.0 AMPERES AC RESISTIVE LOAD AND 10.0 AMPERES DC RESISTIVE LOAD
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 10.0 AMPERES AC INDUCTIVE LOAD AND 10.0 AMPERES DC INDUCTIVE LOAD
ZZZK SPECIFICATION/STANDARD DATA 96906-MS24149 GOVERNMENT STANDARD
CRNG NONPILE-UP MAIN CONTACT ARRANGEMENT 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
ADTV CASE MATERIAL METAL
CRPQ NOMINAL OPERATING CURRENT RATING AND TYPE 250.0 MILLIAMPERES DC SINGLE WINDING
AEBV UNTHREADED MOUNTING HOLE DIAMETER 0.173 INCHES NOMINAL FIRST MOUNTING FACILITY
CRXH TIME DELAY 0.01 SECONDS MAXIMUM FIXED RELEASE TIME
TTQY TERMINAL TYPE AND QUANTITY 8 SCREW ALL FUNCTIONS
CQYJ MOUNTING FACILITY PATTERN RECTANGULAR SECOND MOUNTING FACILITY
AEBV UNTHREADED MOUNTING HOLE DIAMETER 0.173 INCHES NOMINAL SECOND MOUNTING FACILITY

Similar Parts