Part Number
Definition:
AN ITEM CONSISTING OF INSULATING MATERIAL, WHICH IS SPECIFICALLY DESIGNED TO HAVE FASTENED THEREON, OR ON WHICH ARE FASTENED TERMINAL(S), SUCH AS SCREWS, SOLDER LUGS, SOLDER STUDS, SOLDERLESS CONNECTORS, CLIPS, AND THE LIKE. IT IS USUALLY USED FOR JUNCTIONS OR TERMINATIONS OF WIRE OR CABLE ASSEMBLIES. IT DOES NOT INCLUDE ITEMS AS DEFINED ABOVE WITH PARTS, SUCH AS RESISTORS AND CAPACITORS MOUNTED THEREON. DO NOT USE IF A MORE SPECIFIC NAME EXISTS, SUCH AS FUSEHOLDER; HOLDER, RESISTOR; FANNING STRIP; CONTACT ASSEMBLY, ELECTRICAL; JACK ASSEMBLY, TIP; CHAMBER, CABLE TERMINAL; PANEL (2) (AS MODIFIED); CONNECTOR (AS MODIFIED). EXCLUDES TERMINAL, STUD; TERMINAL, FEEDTHRU, INSULATED; POST, BINDING, ELECTRICAL; AND CHASSIS, ELECTRICAL-ELECTRONIC EQUIPMENT. FOR ITEMS HAVING PRINTED ELECTRICAL CONDUCTOR PATHS, SEE PRINTED WIRING BOARD.
CAGE Information
Code | Company |
---|---|
03497 | GENERAL ELECTRIC CO OUTDOOR BREAKER |
Federal Supply Class
Title
LUGS, TERMINALS, AND TERMINAL ST
Inclusions:
INCLUDES BINDING POSTS; BATTERY CLIPS; STUD TERMINALS; TEST CLIPS.
Exclusions:
EXCLUDES CAPS, ELECTRICAL; CLIPS, ELECTRICAL; AND CONTACTS, ELECTRICAL.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
SFTT | SURFACE TREATMENT | CADMIUM TERMINALS |
SFTT | SURFACE TREATMENT | CADMIUM TERMINALS |
MATT | MATERIAL | PLASTIC BOARD |
ABGR | BOARD HEIGHT EXCLUDING TERMINALS | 1.250 INCHES |
FEAT | SPECIAL FEATURES | FOUR SELF TAPPING SCREWS INCLUDED,TO FIT PILOT HOLES AT EACH CORNER OF BOARD |
ABGS | BASE THICKNESS | 0.625 INCHES |
AAMA | MOUNTING HOLE DIAMETER | 0.219 INCHES |
ABDU | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 5.375 INCHES |
ABCS | TERMINAL ROW QUANTITY | 2 |
CWLG | TERMINAL PATTERN ARRANGEMENT | MULTI-ROW |
MATT | MATERIAL | STEEL TERMINALS |
ABGQ | BOARD OVERALL HEIGHT | 1.250 INCHES |
CWLN | TERMINAL DESIGN | NONFEEDTHRU |
CRNL | NONFEEDTHRU TERMINAL TYPE | 857 SINGLE |
ABCU | DISTANCE BETWEEN TERMINAL ROW CENTERS | 1.000 INCHES |
ABDX | DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITY | 0.188 INCHES |
ABGP | BOARD OVERALL WIDTH | 2.000 INCHES |
ABCX | BOARD CONSTRUCTION | HOLLOW CONSTRUCTION WITHOUT INSULATED STRIP |
ABDW | DISTANCE FROM BOTTOM EDGE OF TERMINAL BOARD TO CENTER OF MOUNTING HOLE | 1.000 INCHES |
ABGN | BOARD OVERALL LENGTH | 5.750 INCHES |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE |
ABCT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.625 INCHES |
CSCS | NONFEEDTHRU TERMINAL QUANTITY | 8 SINGLE |
AAQL | BODY STYLE | BARRIER TYPE |