National Stock Number (NSN) Output Data
Definition:
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
SRX-701 | 4S405 | A | 3 | 2 | 4 | ZZ | ||
00-004-51 | 89875 | A | 5 | 1 | 4 | ZZ | ||
0200701 | 4S405 | A | 3 | 2 | 4 | ZZ |
CAGE Information
Code | Company |
---|---|
4S405 | KONICA MINOLTA MEDICAL IMAGING U.S.A |
89875 | DEFENSE LOGISTICS AGENCY DIRECTORATE |
Federal Supply Class
Title
IMAGING EQUIPMENT AND SUPPLIES:
Inclusions:
INCLUDES MEDICAL X-RAY FILM; MEDICAL X-RAY FILM VIEWING EQUIPMENT; MEDICAL X-RAY FILM PROCESSING AND FINISHING EQUIPMENT AND SUPPLIES; X-RAY TUBES; COMPUTERIZED TOMOGRAPHY (CT) SCANNERS AND RELATED EQUIPMENT; MAGNETIC RESONANCE IMAGING MACHINE AND RELATED EQUIPMENT; POSITRON EMISSION TOMOGRAPHY (PET) SCANNERS AND RELATED EQUIPMENT; COMPUTED AND/OR DIRECT DIGITAL RADIOGRAPHY MACHINES AND RELATED EQUIPMENT; ULTRASOUND AND ECHOCARDIOGRAM SCANNERS AND RELATED EQUIPMENT; SCINTIGRAPHY EQUIPMENT; MEDICAL PICTURE ARCHIVING AND COMMUNICATION SYSTEMS (PACS) EQUIPMENT; MEDICAL THERMAL IMAGING EQUIPMENT; OPTICAL COHERENCE TOMOGRAPHY (OCT) SPECTROSCOPY MACHINES AND RELATED EQUIPMENT; AND IMAGING SUPPLIES AND CONTRAST DELIVERY SYSTEMS THAT ARE NOT USED BY OTHER MEDICAL DISCIPLINES.
Exclusions:
EXCLUDES INDUSTRIAL IMAGING EQUIPMENT (X-RAY, THERMAL AND THE REST;) SUPPLIES AND EQUIPMENT THAT CAN BE USED BY OTHER MEDICAL DISCIPLINES (SEE MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT AND SUPPLIES AND HOSPITAL AND SURGICAL CLOTHING AND RELATED SPECIAL PURPOSE ITEMS.)
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABHP | OVERALL LENGTH | 30.800 INCHES NOMINAL |
ATAB | FILM ACCOMMODATION TYPE | CUT SHEET |
ABMK | OVERALL WIDTH | 29.500 INCHES NOMINAL |
CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | PROCESSING MACHINE PHOTOGRAPHIC FILM 35.4X17.5X24IN |
AKCV | DRIVE TYPE | ANY ACCEPTABLE |
FEAT | SPECIAL FEATURES | SRX-701 HIGHLY VERSATILE MULTI-SPEED HARD COPY MEDICAL IMAGING PROCESSING SYSTEM USED IN CONJUCTION WITH KONICA SR-SERIES FILMS; ALLOWS FOR THE INSTANT SELECTION OF OTHER PROCESSING CYCLES INCLUDING 60,90,110,180 SECONDS (LEADING-EDGE-TO-LEADING-EDGE) USING ALL STANDARD RADIOGRAPHIC CUT SHEET FILM; KONICA SR SERIES ORTHOCHROMATIC AND SINGLE EMULSION FILMS REQUIRED FOR 45 SECOND PROCESSING; ALL PROCESSING PARAMETERS SUCH AS TEMPERATURE AND REPLENISHMENT ARE AUTOMATICALLY ADJUSTED TO MATCH EACH CYCLE WHEN SELECTED |
ELEC | VOLTAGE IN VOLTS | 200.0 AND 240.0 |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL AND 80.0 HERTZ MAXIMUM |
ABKW | OVERALL HEIGHT | 43.300 INCHES NOMINAL |
ACDC | CURRENT TYPE | AC |
FAAZ | PHASE | SINGLE |
BHZY | FILM SIZE ACCOMMODATED | 10 IN. BY 12 IN. THROUGH 14 IN. BY 17 IN. |