Part Number
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
CAGE Information
Code | Company |
---|---|
13499 | ROCKWELL COLLINS INC. DBA GOVERNMENT |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
ADAU | BODY HEIGHT | 5.500 INCHES MAXIMUM |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT |
ADAQ | BODY LENGTH | 5.250 INCHES NOMINAL |
ADAT | BODY WIDTH | 4.375 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
CWJS | WINDING OPERATING VOLTAGE | 29.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 4.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CWJS | WINDING OPERATING VOLTAGE | 15.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY |
AAJF | THREAD DIRECTION (NON-CORE) | RIGHT-HAND SINGLE GROUP |
ACZB | FREQUENCY RATING | 47.0 HERTZ MINIMUM SINGLE COMPONENT AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT |
CQLC | WINDING TAP LOCATION (NON-CORE) | CENTER TAP SINGLE COMPONENT ALL SECONDARY |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE GROUP |
THSD | THREAD SERIES DESIGNATOR | UNF SINGLE GROUP |
AAJD | THREAD CLASS (NON-CORE) | 2A SINGLE GROUP |
CQLC | WINDING TAP LOCATION (NON-CORE) | TAP W/CENTER TAP SINGLE COMPONENT ALL PRIMARY |
CQJX | NOMINAL THREAD SIZE | 0.190 INCHES SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 12 TAB, SOLDER LUG AND 3 WIRE HOOK |