A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
CAGE Information
Code | Company |
---|---|
13499 | ROCKWELL COLLINS INC. DBA GOVERNMENT |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
ADAT | BODY WIDTH | 3.800 INCHES MAXIMUM |
CWJS | WINDING OPERATING VOLTAGE | 15.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST PRIMARY AND 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST PRIMARY |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AXGY | MOUNTING METHOD | BRACKET SINGLE GROUP AND SLOT SINGLE GROUP |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT |
CQLC | WINDING TAP LOCATION (NON-CORE) | TAP W/O CENTER TAP SINGLE COMPONENT 1ST PRIMARY |
ACZB | FREQUENCY RATING | 47.0 HERTZ MINIMUM SINGLE COMPONENT AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
ABTD | MOUNTING SLOT WIDTH | 0.200 INCHES NOMINAL SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND PRIMARY |
CQLC | WINDING TAP LOCATION (NON-CORE) | MULTIPLE TAPS W/CENTER TAP SINGLE COMPONENT ALL SECONDARY |
ADAU | BODY HEIGHT | 3.300 INCHES MAXIMUM |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 4.000 INCHES MAXIMUM |
TTQY | TERMINAL TYPE AND QUANTITY | 15 TAB, SOLDER LUG |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |