National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
AMMETER
Definition:
AN INSTRUMENT WHICH MEASURES ELECTRIC CURRENT AND IS CALIBRATED AND MARKED IN AMPERES OR ANY MULTIPLE AND/OR SUBMULTIPLE THEREOF. THE VALUE MAY BE EXPRESSED BY MEANS OF A POINTER AND CALIBRATED DIAL OR A DIGITAL READOUT DISPLAY. FOR CURRENT DETECTING TYPE OF DEVICES, SEE GALVANOMETER.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
PL JWP-36-C150 IT148 | 71871 | A | 5 | 9 | 5 | ZZ | ||
9842189108 | 71871 | A | 5 | 2 | 5 | ZZ | ||
984.21891.08 | 71871 | A | 3 | 2 | A | ZZ |
CAGE Information
Code | Company |
---|---|
71871 | ALFA LAVAL INC. |
Federal Supply Class
Title
ELECTRICAL AND ELECTRONIC PROPER
Inclusions:
INCLUDES TEST LEADS AND TEST LEAD ATTACHMENTS; TEST INSTRUMENTS DESIGNED FOR COMMUNICATION EQUIPMENT; TEST INSTRUMENTS DESIGNED FOR USE WITH ELECTRONIC EQUIPMENT CLASSIFIED IN TWO OR MORE FSC GROUPS.
Exclusions:
EXCLUDES RADIAC EQUIPMENT
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
AWZJ | POWER SOURCE | EXTERNAL |
SUPP | SUPPLEMENTARY FEATURES | HAS FOUR ALTERNATE MTG. HOLES |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 643.5 MILLIMETERS NOMINAL |
APSN | PANEL FOR WHICH DESIGNED | MAGNETIC OR NONMAGNETIC |
FEAT | SPECIAL FEATURES | DELAYED SHUT-DOWN |
AKYN | FURNISHED ITEMS AND QUANTITY | AMMETER 1 |
BFQP | DISPLAY DIGIT QUANTITY | 6 |
AMQY | INSTALLATION DESIGN | PANEL OR RACK |
BHSX | CIRCUIT CONSTRUCTION TYPE (NON-CORE) | ELECTRONIC, SOLID STATE |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ANRL | MOUNTING ARRANGEMENT STYLE | FOUR HOLE/STUD RECTANGULAR/SQUARE |
BFQN | DISPLAY TYPE | LIGHT EMITTING DIODE |
MARK | SPECIAL MARKINGS | START-STOP; RESET. |
AQEC | MOVEMENT TYPE | ELECTROSTATIC |
ZZZV | FSC APPLICATION DATA | TEST AND MEASURING EQUIPMENT |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 410.5 MILLIMETERS NOMINAL |
AACT | CIRCUIT CURRENT FOR WHICH DESIGNED | AC |
CTTD | CIRCUIT ATTACHMENT METHOD AND QUANTITY | 1 PRINTED CIRCUIT |
FAAZ | PHASE | SINGLE |
AMKD | INDICATOR TYPE | DIGITAL DISPLAY |