National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
PLUG-IN UNIT , ELECTRICAL-ELECTRON
Definition:
AN ELECTRONIC SUBASSEMBLY DESIGNED TO BE PLUGGED INTO ONE OR MORE BASIC PIECES OF TEST EQUIPMENT TO EXTEND THE CAPABILITIES OF THE BASIC INSTRUMENT. THE BASIC INSTRUMENT CANNOT FUNCTION WITHOUT ONE OR MORE PLUG-IN UNITS (AS REQUIRED) IN POSITION.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
SR5020A | 5J927 | A | 3 | 2 | 4 | ZZ | ||
96000002-01 | 0DRX9 | A | 7 | 2 | 5 | ZZ |
CAGE Information
Code | Company |
---|---|
0DRX9 | ADVANCED TESTING TECHNOLOGIES INC DB |
5J927 | INTERFACE TECHNOLOGY INC |
Federal Supply Class
Title
ELECTRICAL AND ELECTRONIC PROPER
Inclusions:
INCLUDES TEST LEADS AND TEST LEAD ATTACHMENTS; TEST INSTRUMENTS DESIGNED FOR COMMUNICATION EQUIPMENT; TEST INSTRUMENTS DESIGNED FOR USE WITH ELECTRONIC EQUIPMENT CLASSIFIED IN TWO OR MORE FSC GROUPS.
Exclusions:
EXCLUDES RADIAC EQUIPMENT
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AGAV | END ITEM IDENTIFICATION | BENCHTOP RECONFIGURABLE AUTOMATIC TESTER (BRAT) |
FEAT | SPECIAL FEATURES | 50MHZ DIGITAL INTERFACE MODULE, 32 INPUTS AND 32 OUTPUTS, MEMORY TYPES INCLUDE STIMULUS; OUTPUT; TRISTATE; ALGORITHMIC RESPONSE RECORD; EXPECT; MASK, MEMORY DEPTH 65500 VECTORS, OPERATING TEMPERATURE RANGE 0 TO +45 DEGREES CELCIUS; STORAGE TEMPERATURE RANGE -40 TO +75 DEGREES CELCIUS |
CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | MODULE, INTERFACE |