Part Number
Definition:
A CHAMBER DESIGNED EXCLUSIVELY TO PERFORM CONTROLLED TESTS UNDER SIMULATED ENVIRONMENTAL CONDITIONS TO DETERMINE PHYSICAL CHANGES OR DAMAGE TO ITEMS UNDER TEST DUE TO HUMIDITY, IMMERSION, MOISTURE, ALTITUDE THERMAL SHOCK, SAND, DUST, ETC..
CAGE Information
Code | Company |
---|---|
99998 | DEFENSE SUPPLY CENTER RICHMOND INDUS |
Federal Supply Class
Title
ENVIRONMENTAL CHAMBERS AND RELAT
Inclusions:
INCLUDES CHAMBERS; WIND TUNNELS; ENCLOSURES SPECIFICALLY DESIGNED TO SIMULATE AN ENVIRONMENTAL CONDITION; WEATHEROMETERS; FADEOMETERS; SPECIALLY DESIGNED EQUIPMENT AND COMPONENTS EXCLUSIVELY RELATED TO ENVIRONMENTAL CHAMBERS.
Exclusions:
EXCLUDES GENERAL PURPOSE PREFABRICATED BUILDINGS, CHAMBERS, PANELS, AND COMPONENTS (FSC 5410); CONTROLLED ENVIRONMENTAL CONDITIONING KITS AND SETS (FSC 4240); BATHS (FSC 4510); OVENS (FSC 7310); KILNS (FSC 3630); RADIOSONDE BASELINE CHECK SETS (FSC 6660); DIVERS RECOMPRESSION CHAMBERS (FSC 4220); ALTITUDE TRAINING DECOMPRESSION CHAMBERS (FSC 6930); AND CHAMBERS USED AS TRAINING DEVICES (FSC 6930); CHECKOUT AND TEST EQUIPMENT (FSC 6625); CHEMICAL ANALYSIS INSTRUMENTS (FSC 6630); ELECTRICAL AND ELECTRONIC PROPERTIES MEASURING AND TESTING INSTRUMENTS (FSC 6625); AND METEOROLOGICAL INSTRUMENTS (FSC 6660).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
FEAT | SPECIAL FEATURES | INSIDE DIAMETER OF CHAMBER 48 INCHES; DOOR EQUIPPED WITH 9 INCH VIEWING PORT FOR OBSERVATION OF THE EXPLOSIVE CYCLE; CHAMBER INCLUDES GAGES TO INDICATE THE PRESSURE, TEMPERATURE AND ALTITUDE; BUTANE GAS INTRODUCED INTO THE CHAMBER THROUGH A GAS METER WHICH MEASURES THE VARYING EXPLOSIVE MIXTURES NECESSARY FOR THE TEST; EXPLOSION SWITCH MANUALLY OPERATED |
FEAT | SPECIAL FEATURES | INSIDE DIAMETER OF CHAMBER 48 INCHES; DOOR EQUIPPED WITH 9 INCH VIEWING PORT FOR OBSERVATION OF THE EXPLOSIVE CYCLE; CHAMBER INCLUDES GAGES TO INDICATE THE PRESSURE, TEMPERATURE AND ALTITUDE; BUTANE GAS INTRODUCED INTO THE CHAMBER THROUGH A GAS METER WHICH MEASURES THE VARYING EXPLOSIVE MIXTURES NECESSARY FOR THE TEST; EXPLOSION SWITCH MANUALLY OPERATED |
MATL | MATERIAL | STEEL |
AFPV | COMPARTMENT QUANTITY | 1 |
CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | EXPLOSION CHAMBER |
ABFY | OVERALL DEPTH | 60.000 INCHES NOMINAL |
BHJQ | DOOR | PROVIDED |
CWZY | ENVIRONMENTAL CHAMBER TYPE | EXPLOSIVE |