National Stock Number (NSN) Output Data
Definition:
A CHAMBER DESIGNED EXCLUSIVELY TO PERFORM CONTROLLED TESTS UNDER SIMULATED ENVIRONMENTAL CONDITIONS TO DETERMINE PHYSICAL CHANGES OR DAMAGE TO ITEMS UNDER TEST DUE TO HUMIDITY, IMMERSION, MOISTURE, ALTITUDE THERMAL SHOCK, SAND, DUST, ETC..
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
S1.2C MODIFIED | 20824 | A | 3 | 2 | 4 | ZZ | ||
S1.2C | 20824 | A | 5 | 1 | 4 | ZZ |
CAGE Information
Code | Company |
---|---|
20824 | THERMOTRON INDUSTRIES |
Federal Supply Class
Title
ENVIRONMENTAL CHAMBERS AND RELAT
Inclusions:
INCLUDES CHAMBERS; WIND TUNNELS; ENCLOSURES SPECIFICALLY DESIGNED TO SIMULATE AN ENVIRONMENTAL CONDITION; WEATHEROMETERS; FADEOMETERS; SPECIALLY DESIGNED EQUIPMENT AND COMPONENTS EXCLUSIVELY RELATED TO ENVIRONMENTAL CHAMBERS.
Exclusions:
EXCLUDES GENERAL PURPOSE PREFABRICATED BUILDINGS, CHAMBERS, PANELS, AND COMPONENTS (FSC 5410); CONTROLLED ENVIRONMENTAL CONDITIONING KITS AND SETS (FSC 4240); BATHS (FSC 4510); OVENS (FSC 7310); KILNS (FSC 3630); RADIOSONDE BASELINE CHECK SETS (FSC 6660); DIVERS RECOMPRESSION CHAMBERS (FSC 4220); ALTITUDE TRAINING DECOMPRESSION CHAMBERS (FSC 6930); AND CHAMBERS USED AS TRAINING DEVICES (FSC 6930); CHECKOUT AND TEST EQUIPMENT (FSC 6625); CHEMICAL ANALYSIS INSTRUMENTS (FSC 6630); ELECTRICAL AND ELECTRONIC PROPERTIES MEASURING AND TESTING INSTRUMENTS (FSC 6625); AND METEOROLOGICAL INSTRUMENTS (FSC 6660).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
BQMJ | CABINET INNER WALL MATERIAL | STEEL |
SURF | SURFACE TREATMENT | LACQUER, FED SPEC 595-25185 |
AFMQ | INSIDE HEIGHT | 12.000 INCHES NOMINAL |
BLST | INSULATED CABINET | PROVIDED |
AFMW | OUTSIDE HEIGHT | 41.000 INCHES NOMINAL |
MATL | MATERIAL | STEEL |
AFEF | INSIDE DEPTH | 11.000 INCHES NOMINAL |
CWZY | ENVIRONMENTAL CHAMBER TYPE | TEMPERATURE |
ADJT | INSIDE WIDTH | 16.000 INCHES NOMINAL |
ADJV | OUTSIDE WIDTH | 30.000 INCHES NOMINAL |
FEAT | SPECIAL FEATURES | PROGRAMMABLE TEMPERATURE CONTROLLER WITH DIGITAL DISPLAY (MODEL 2800);6PANE THERMAL WINDOW WITH SILICONE GASKETS; RS-232C OR IEEE-488 INTERFACE;DRY NITROGEN USED TO REDUCE MOISTURE CONTENT;MODIFIED TO INCLUDE REFRACTOR COLLIMATOR, MOTORIZED TARGET WHEEL AND VIBRATION ISOLATED BASE PLATE;USED TO TEST THE B-52 FLIR SENSOR ASSEMBLY (AN/AAQ-23) AND USED IN CONJUNCTION WITH IR RADIATION SOURCE CONTROL UNIT SR-80-2D |
BNDW | COOLING COILS FOR BELOW ROOM TEMP USE | INCLUDED |
BQMP | OUTER DOOR MATERIAL | STEEL |
ASQJ | OPERATING TEMP RANGE IN DEG CELSIUS | -73.3/+177.0 |
BHGT | CIRCULATION METHOD | MECHANICAL |
AZZH | HEAT SOURCE FOR WHICH DESIGNED | INTEGRAL |
BCXB | OUTSIDE DEPTH | 22.000 INCHES NOMINAL |
AMSE | VOLTAGE RATING | 115.0 VOLTS NOMINAL |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL |
BQMR | OUTER DOOR INSULATION FEATURE | INCLUDED |
AFPM | ASSEMBLY FORM | ASSEMBLED |
AKYD | ACCESSORY COMPONENTS AND QUANTITY | 2 1/2 HORSEPOWER COMPRESSORS |
ANPT | POWER RATING | 40.0 VOLT-AMPERE NOMINAL |
BDWT | HEATING METHOD | ELECTRICAL |
BQMH | CABINET OUTER WALL MATERIAL | STEEL |
BQMN | OUTER DOOR QUANTITY | 1 |
ACDC | CURRENT TYPE | AC |
HUES | COLOR | BLUE |
BGXH | WATER JACKET | PROVIDED |
BHJQ | DOOR | PROVIDED |
BQML | CABINET MOUNTING TYPE | STAND |
FAAZ | PHASE | SINGLE |